background image

Be sure to charge the battery sufficiently prior to operation. Fill the barrel with prepared liquid through the screen and 
close  the  barrel  cover.  Observe  to  check  whether  leakage  occurs  to  the  bottom  of  barrel  or  not.  Turn  on  the  power 
switch and clench the switch handle to start spraying. Either instant or continuous spraying is allowed. 
Three kinds of nozzles are supplied to cater for your demands 
 

5.

 

Notes 

6

 

The battery has been charged before being delivered. However, it will self-discharge in the course of 

transportation and storage. Additional charging before initial use thus is required. 

7

 

Try your best to avoid operating the sprayer without water in it which may damage the diaphragm. 

Never place the sprayer upside down . Otherwise the battery may be damaged. 

8

 

In case of bumming heard from inside the sprayer or poor atomization after long time use, it shows 

low batter voltage and requires timely charging. Connect the plug of charge to “Charging ” jack without 
removing the battery from the sprayer. For each charging, a duration of at least 8 hours is required. The 
charger shall be put at a dry , well-ventilated, safe place over 50 cm high above the ground. 

9

 

Trial spraying with clean water is necessary for initial use ,so as to make sure neither leakage nor poor 

atomization occurs. 

10

 

There are a few points the operator should remember when spraying: 

*

 

Wearing of mask and gloves is required. Never operate when spraying: contact your body. 

Never spray the pesticide against the wind, Never spray at human, animals or food. Never 
operate for a long time under high temperature. Never drink alcohol immediately after 
spraying. Strict compliance with safety instructions of pesticide manufacturer is required 
while handling the pesticide. 

*

 

Never operate with such special liquid as strong acid, strong base and flammable goods. 

Never use high -persistent and very toxic pesticides for pest controlling purposes on 
vegetables, fruit trees, tee and medical plants. 

*

 

The unit shall be cleaned thoroughly after each use so as to avoid corrosion , clogging and 

mixing of residual liquid with liquid of next spraying which may do harm to crops or reduce 
the effects. Cleaning way: for exterior, scrub with a dampened cloth. For interior, fill with 
small amount of water and shake before turning on the power to discharge. 

 

6.

 

In case of short-term operations, charging is not required for each use. In case of long-term storage, 

regular full discharging and recharging with an interval of half a month, a month or two month  or are required 
to ensure the service life of battery. 

7.

 

Don ’ t operate this Sprayer at a place with a temperature exceeding 45'C or lower than -10°C. 

8.

 

After use for half a year, you should dismantle the base and check whether the screws loose or not. 

If loose, please tighten them. 

*

 

Be sure to switch off the power before storage. 

*

 

It’ s strictly prohibited to keep this Sprayer near fire or expose the base to water or immerse 

the machine in the water for cleaning or filling of water. 

*

 

Never spray powders or particles with this Sprayer. 

*

 

Unauthorized removing of the charger’ s housing is prohibited. 

Problems

 

Causes

 

Solutions

 

The motor fails to start after 
being powered on.

 

1.

 

The power cables come off.

 

2.

 

The battery is out of power.

 

3.

 

The power switch has been damaged

 

1.

 

Dismantle the base to connect the cables 

soundly.

 

2.

 

Charging.

 

3.

 

Replace the switch.

 

Abnormal sound heard In the 
motor.

 

• The fastening screws of pump loose.

 

Tighten the screws.

 

Leakage occurs to the bottom of 
base

 

• The inlet and outlet tubes of pump break or 
loose at the joints.

 

• Dismantle the base and tighten the tube clamp; 
Repair.

 

Poor atomization

 

1.

 

The spraying hole was clogged.

 

2.

 

Spraying hole and split sheet wore out.

 

3.

 

Spraying sheet inversely mounted

 

4.

 

Filter screen was clogged.

 

5.

 

Leakage occurred to tubes at joints.

 

6.

 

Batter short of power

 

7.

 

Air remained in the pump.

 

1.

 

Remove foreign matters,

 

2.

 

Replace the spraying sheet and split 

sheet

 

3.

 

Correct

 

4.

 

Clean

 

5.

 

Tighten.

 

6.

 

The alarm out of order, replace it; 

charge.

 

7.

 

Remove the nozzle or spraying rod to 

discharge the air.

 

Summary of Contents for KF-16C-23

Page 1: ...t les orifices de la buse entass s L cran est con u express ment pour permettre un d montage facile pour le nettoyage d Circuit d alarme sous tension En cas de travail prolong l alarme de la batterie...

Page 2: ...mais asperger les pesticides en cas de vent jamais en direction des personnes des animaux et de la nourriture Ne pas utiliser l appareil pendant de longues p riodes haute temp rature Juste apr s le tr...

Page 3: ...ux d entr e et de sortie de la pompe sont cass s ou desserr s aux jointures D monter la base et serrer les bornes R parer Faible aspersion 1 L orifice d aspersion est obstru 2 L orifice d aspersion et...

Page 4: ...to prevent foreign matters or particles from clogging the Nozzle The screen is uniquely structured to allow easy dismantle for cleaning i With under voltage alert circuit In case of prolonged operati...

Page 5: ...ables fruit trees tee and medical plants The unit shall be cleaned thoroughly after each use so as to avoid corrosion clogging and mixing of residual liquid with liquid of next spraying which may do h...

Page 6: ...kg 6 adjustable stainless steel lance 7 Pump 3 8L MIN automatic pump 8 with regulator 16L Knapsack electric sprayer with wheels 1 Tank Material PE 2 Capacity 16L 3 Battery 12V 12A 4 working pressure 0...

Page 7: ...Model KF 16C 23 KF 16C 9 KF16C 26 KF 16C11 Fertilizer 16L KF 18C 2 Anno di costruzione 2015 conforme a tutte le disposizioni pertinenti della direttiva europea 2006 42 CE recepita in Italia dal D lgs...

Reviews: