18
Tankfulls: nn
0000:00:00:00
The Tankfulls display shows the total number of times the tankfull alarm has been activated (since
being put into service), due to a full recovery tank, along with a time record of when the unit last had a
tankfull alarm. This display can be used to determine how long it takes the recovery tank to fill or if a
larger tank is required.
Low Batts: nn
0000:00:00:00
The Low Batts display shows the total number of times the unit has experienced a low battery condition
(since being put into service) along with a time record of when the unit last had a low battery condition.
This display can help in evaluating battery usage (in comparison to how much product is being
recovered) showing the need for either a cycle adjustment or the need for additional solar panels. It can
also help in determining if the battery is losing its ability to maintain a charge.
The Solar Sipper controller is designed to shut itself down when the battery voltage reaches 11.4V and
will resume operation when the battery charge reaches 12.1V. The Solar Sipper is designed to charge
the battery to a maximum of 14.5V. The system will also display a low battery condition when the
battery becomes frozen. Allow the battery to thaw prior to re-charging.
Low Temps: nn
0000:00:00:00
The Low Temps display (when Low Temp Shutoff is enabled during the startup process) shows the
total number of times the unit has experienced a low temperature condition (since being put into
service) along with a time record of when the unit last had a low temperature condition. A low
temperature shutoff (when enabled) will occur at 0°C (32°F).
Temperature:
nnC xxx
The Temperature display shows the current temperature of the unit in Celsius followed by a diagnostic
number.
Battery Voltage:
nn.nV xxxx
The Battery Voltage display shows the current battery voltage for the Sipper system followed by a
diagnostic number.
Ver: v.v Wls: n
ID: iii SS: sss
This final display contains the following information for the Sipper controller:
Where
v.v = software version
n = number of wells for which the unit was designed (1 thru 8)
iii = controller ID
SS = Signal Strength (used on wireless Sippers)
sss = signal strength in a numeric value (used on wireless Sippers)
Summary of Contents for Solar Sipper
Page 1: ...Rev 10 12 2017 Part 16550176 Geotech Sipper Installation and Operation Manual...
Page 2: ...i...
Page 16: ...13 Figure 2 5 Example of Tankfull Probe...
Page 23: ...20 Figure 3 1 Flowchart of User Interface Label...
Page 24: ...21 Figure 3 2 Example of Solar Sipper front panel...
Page 38: ...35 Section 8 System Schematics Figure 8 1 Solar Sipper Schematic...
Page 39: ...36 Figure 8 2 AC Sipper Schematic shown with optional Desiccant Dryers...
Page 40: ...37 Figure 8 3 8 Well Solar Sipper Internal Wiring Diagram...
Page 41: ...38 Figure 8 4 3 Well Solar Sipper Internal Wiring Diagram...
Page 45: ...42 Notes...