6

2.1 Coupling diagram

Control panel

307.GOV

Disconnection switch

Nozzle magnet

Nozzle switch

X1

 - 

1U

2

X1

 - 

1N

2

24VDC

0VDC

24VDC

24VDC

X1 - 1

X1 - 2

Supply 

voltage

230V 50Hz

X1

 - 

1N

1

X1

 - 

1U

1

Control Panel 

307.GOV

Supply 

voltage 

230V 50Hz

X1 - 1N1

X1 - 1U1

X1 - 1N2

X1 - 1

X1 - 2

24VDC

24VDC

24VDC

0VDC

Nozzle 

Switch

Nozzle Magnet

Disconnection switch

X1 - 1U2

Summary of Contents for Magnetic Rail System Premium

Page 1: ...Version 1 0 30 09 2020 R A I L S Y S T E M MRSP Magnetic Rail System Premium I N S T R U C T I O N M A N U A L www geovent com pl ...

Page 2: ...2 ...

Page 3: ... installed correctly the MRSP allows a vehicle to be placed in po sition in a safe manner The hose is extended and fas tened to the exhaust of the vehicle Alternatively the MRSP can be fitted with an extraction arm and be used for welding 1 3 Technical Specifications Temperature extracted air Max 170 C Temperature surroundings Min 0 50 C If the extracted air is hotter than 170 C the standard hose ...

Page 4: ... carried out by a trained profes sional Before installing consider the optimal placement for the Magnetic rail system Is there sufficient room and is it possible to perform duct work and service the system The Magnetic rail system can be installed on both a plane and slanted ceiling Depending on the individual solution some components may not be included The nozzle for exhaust pipes at high level ...

Page 5: ...g to the drawing and point at right angles or up to max 45 backwards The pipe should be straight and lie flush with or be slightly angled out from the side of the vehicle Be aware that it may be necessary to make modificati ons to the exhaust system of the vehicle to ensure the best possible position of the exhaust pipe When the hose and the nozzle are connected to the ve hicle the hose should for...

Page 6: ...ozzle magnet Nozzle switch X1 1U2 X1 1N2 24VDC 0VDC 24VDC 24VDC X1 1 X1 2 Supply voltage 230V 50Hz X1 1N1 X1 1U1 Control Panel 307 GOV Supply voltage 230V 50Hz X1 1N1 X1 1U1 X1 1N2 X1 1 X1 2 24VDC 24VDC 24VDC 0VDC Nozzle Switch Nozzle Magnet Disconnection switch X1 1U2 ...

Page 7: ...ed for other purposes than described in this manual The fan is turned off This will result in the hose melting The flexible hose can withstand 170 C for con tinuous running Use at higher temperatures will shorten the life of the product Therefore avoid tasks that require extended periods of continous running which will generate high exhaust tem peratures 4 0 Maintenance Periodic maintenance Mainta...

Page 8: ...ent A S in relation to loss of earnings or consequential loss as a result of defects on products from Geovent Wear on parts such as filter cartridges and hose is not included in the warranty User liability In order for Geovent to be capable of granting the decla red warranty the user fitter must follow this Instruction manual in all respects Under no circumstances may the products be changed in an...

Page 9: ...ic rail system Premium has been manufactured in compliance with the following directives and standards European Parliament and Council Directive 2006 42 EC of 17 May 2006 on machinery and amendments to Directive 95 16 EC Authorized to collect the technical file Lise Cramer Date 30 09 2020 Position Director Name Thomas Molsen Signature ____________________________ 6 0 Declaration of conformity ...