GV-RK1352 / R1352 / DFR1352 Card Reader
17
2
2.2.2 Keypad (GV-RK1352 Only)
When accessing an entry using GV-RK1352, you can enter the door’s PIN code on the
keypad or present the card and then enter the card’s PIN code on the keypad to be granted
access. The access mode is defined on GV-ASManager.
1.
0~9 Number Keys:
Press the number keys to enter the PIN code.
2.
# Key:
Press the # key to confirm the PIN code.
3.
﹡
Key:
Press the
﹡
key to cancel the PIN code.
2.2.3 LED Indicator and Beeper
In standby mode, the LED is blue. When a card is read, the LED flashes green and the
beeper beeps once.
The reader comes with external control wires for Green LED, Red LED and Beeper. You can
connect these control wires to a GV-AS Controller to change the default settings of the LED
and Beeper. For details on how to configure the settings, refer to
2.6
Changing the Settings
of Beeper and LED
later in this installation guide.
Note:
1. You can only connect the LED and beeper wires to GV-AS210 / 2110 / 2120 / 410 /
4110 / 810 / 8110.
2. The LED indicator and beeper functions are currently unavailable for GV-RK1352 when
it is accessed by the built-in keypad.