Administrator Mode
153
3
3.6.1.3 Object Removed
Object Removed can generate an alarm when an object is removed from the specified area.
Up to 4 detection areas can be added. Note that it is recommended
NOT
to overlap the
detection areas when adding multiple detection areas. Select the checkbox next to
Object
Removed
to enable and click
to configure.
Figure 3-43
1. Once enabled, click
to mark the live view with a detection area. Repeat this step to
add another detection area.
2. Drag the nodes of the detection area to mark the boundary for detection.
3. You can use the following functions to reduce false alarm.
◼
Time Threshold:
The minimum period for an object to be absent from the
detection area before an alarm is triggered.
◼
Sensitivity:
Move the slider to adjust the detection.
4. For
Trigger Actions
and
Plan
, follow
Step 6 ~ 7
at the bottom of
3.5.1.1 Cross Line
.