Administrator Mode
165
3
3.6.1.11 Crowd Density Monitoring
With Crowd Density Monitoring, an alarm is triggered when the number of people in a
specified area exceeds the defined alarm threshold. Note this function is only applicable to
GV-EBD4813 / 8800 / 8813, GV-BLFC5800, GV-PTZ5810-IR, GV-TBL4810 / 8804 / 8810,
GV-TDR4803
, and
GV-TVD4810 / 8810
.
Select the checkbox next to
Crowd Density Monitoring
to enable and click
to configure.
Figure 3-53
1. Once enabled, define the detection area on the live view.
2. For
Report Interval(s)
, set the time interval (in seconds) for reporting crowd density data.
3. Under
Crowd Density Alarm
, set the alarm threshold for
Minor Alarm, Major Alarm,
and
Critical Alarm.
The number of people set for
Critical Alarm
accounts for the
largest and
Minor Alarm
the smallest. The value ranges from 1 to 40, and each alarm
will be triggered when the number of people reaches the set threshold.
4. Under
Trigger Actions
, select
on the desired alarm. See details in
Step 6
at the
bottom of
3.5.1.1 Cross Line
.
5. For
Plan
, follow
Step 7 at the bottom of
3.5.1.1 Cross Line
.