Connecting to Power
To connect the power between the electromagnetic lock and the GV-AS Controller, refer to
the diagram as below. Here we use GV-AS410 Controller as an example.
Connect the (+) point on the electromagnetic lock to
COM
on GV-AS410, connect the two (-)
points of the electromagnetic lock and the external power supply together, and connect the (+)
point on the external power supply to
NC
on GV-AS410.
Note:
1.
It is required to connect an external power supply if the total power consumption of the
output devices and readers connected to the GV-AS Controller exceeds
3A
(for GV-AS210
/ 2110),
3.5A
(for GV-AS410 / 4110) or
5A
(for GV-AS810 / 8110).
2.
You may use the power outputs on the GV-AS Controller when the total power consumption
of the output devices and readers connected to the GV-AS Controller is under
3A
(for GV-
AS210 / 2110),
3.5A
(for GV-AS410 / 4110) or
5A
(for GV-AS810 / 8110). Here we use GV-
AS410 Controller as an example.
12
V
GN
D
12
V
GN
D
12
V
GN
D
June 3, 2015
5