background image

 

Connecting to Power 

To connect the power between the electromagnetic lock and the GV-AS Controller, refer to 

the diagram as below. Here we use GV-AS410 Controller as an example. 

  

Connect the (+) point on the electromagnetic lock to 

COM

 on GV-AS410, connect the two (-) 

points of the electromagnetic lock and the external power supply together, and connect the (+) 

point on the external power supply to 

NC

 on GV-AS410. 

 

Note:  

1. 

It is required to connect an external power supply if the total power consumption of the 
output devices and readers connected to the GV-AS Controller exceeds 

3A 

(for GV-AS210 

/ 2110), 

3.5A 

(for GV-AS410 / 4110) or 

5A

 (for GV-AS810 / 8110). 

2. 

You may use the power outputs on the GV-AS Controller when the total power consumption 
of the output devices and readers connected to the GV-AS Controller is under

 3A 

(for GV-

AS210 / 2110), 

3.5A 

(for GV-AS410 / 4110) or 

5A

 (for GV-AS810 / 8110). Here we use GV-

AS410 Controller as an example. 

12

V

GN

D

12

V

GN

D

12

V

GN

D

 

June 3, 2015 

 

5

 

Summary of Contents for GV-ML600

Page 1: ...June 3 2015 1 1 GV ML600 electromagnetic lock x 1 2 Magnet faceplate x 1 3 Inner hexagon wrench x 1 4 M8 35mm screw black rubber spacer x 1 5 Hat nut x 1 6 Galvanized steel rivet x 2 7 Black rubber spacer x 2 8 Aluminum shim x 2 9 10 5 8 screw x 2 10 10 1 25 screw x 8 11 Washer x 2 12 Stainless steel bracket x 1 13 CU1201 screw permanent magnet x 1 14 M4 6mm screw x 1 15 Inner hexagon nut x 1 16 A...

Page 2: ... 1 Install the electromagnetic lock to the doorframe Note If the power switch is not wired between the DC source voltage and the magnet it will take longer to de energize the magnet simulating residual magnetism Switch or solid state switching device Switch or solid state switching device Correct Incorrect June 3 2015 2 ...

Page 3: ...door Typical Installation of the electromagnetic lock Note To make the armature plate adjust its proper position to the magnet automatically do not fix the armature plate too tightly and make the rubber washer more flexible June 3 2015 3 ...

Page 4: ...er source 2 Power Switch Jumper Plug the power jumpers to Pins 1 2 and Pins 3 4 for a 12V DC power source Plug the power jumper to Pins 2 3 for a 24V DC power source 3 Sensor Connects to the access control system by using the black and red wires For details see Connecting to the GV AS Controller later in this installation guide June 3 2015 4 ...

Page 5: ...supply to NC on GV AS410 Note 1 It is required to connect an external power supply if the total power consumption of the output devices and readers connected to the GV AS Controller exceeds 3A for GV AS210 2110 3 5A for GV AS410 4110 or 5A for GV AS810 8110 2 You may use the power outputs on the GV AS Controller when the total power consumption of the output devices and readers connected to the GV...

Page 6: ...ensor to the GV AS410 connect the Red wire of the sensor to the Input of the GV AS410 and connect the Black wire of the sensor to the Ground of the GV AS410 2 On the Web interface of the GV AS410 select Input Configuration under Advanced Setting and select an input type and input function for the connected sensor from the electromagnetic lock June 3 2015 6 ...

Page 7: ...ation and Output Configuration section in Chapter 8 of the GV AS Controller User s Manual Specifications Voltage DC 12V 24V Current 500mA at 12V 250mA at 24V Holding Force 272 15 kg 600 lb Operating Temperature 20 C 60 C 4 F 140 F Dimensions L x W x H 250 x 47 2 x 26 6 mm 9 84 x 1 86 x 1 05 Armature Plate Dimensions L x W x H 185 x 38 x 12 5 mm 7 28 x 1 50 x 0 49 Weight 2 2 kg 4 85 lb Certificatio...