EGE-MSI-16416
1 6 x 1 6 M o d u l a r i z e d E n c l o s u r e
( 4 8 2 m m × 4 8 4 m m × 1 4 5 m m )
3
6. OPERATION CONTROLS AND FUNCTIONS
6.1 Front Panel
POWER
RETURN
7
8
9
LOCK
MENU
PAGE
6
5
4
SAVE
3
2
1
RECALL
ALL
PAGE
+
0
OUT/IN
ENTER
LOCK
STANDBY
1
11
12
13
14
7
8
9 10
2
3
6
4
5
1
LCM:
Displays the setting information of each input/output and other setting information
according to the selected mode.
2
IR WINDOW:
Accepts the IR remote control signal for the matrix only.
3
POWER:
Press this button to turn the matrix on or press it again to put the matrix into
standby mode. The LED will illuminate when the unit is in standby mode.
Note: If the LED is flashing it means the temperature inside is too high and air circulation
may have been restricted.
4
PAGE ( / / / ):
Use these buttons to cycle through the LCM’s pages for
displaying the current I/O status or when entering into the settings menu.
5
RETURN:
Press this button to return back or exit the current selection.
6
MENU:
Press this button to enter the menu to change the following settings:
• EDID: Support 3 EDID modes.
1. Standard Mode: Uses the built-in EDID settings that support video up to 1080p@60
or WUXGA@60 (RB) video and LPCM 2CH audio.
2. Dynamic Mode: Reads the EDID settings from the display connected to the lowest
numbered output port.
3. Manual Mode: Supports independent EDID settings by selecting the input and output
ports.
• IP: Displays the setting information of IP address, IP Netmask and IP Gateway.
• Temperature: These figures show the internal temperature of the matrix.
• LCM: Supports LCM contrast range from 1 to 4.
7
ALL:
Press this button to assign the same input to all outputs.