Offline Operation
Plotter Parameters
4-19
Saving Parameters
Use the Save Param function to permanently save changes made to parameter
settings. Settings stored using Save Param remain in effect even after plotter
power is turned off.
T
O PERMANENTLY SAVE NEW PARAMETER SETTINGS
1. From page one of the Offline menu, press the Menu key one time to
display page two.
2. From page two of the Offline menu, press
F2-Param Entry to display page
one of the Parameter Entry menu.
3. Press
F3-Save Param. The message “Storing Parameters” appears briefly,
then the Param Entry menu reappears.
4. From page one of the Parameter Entry menu, press
F4-Exit until page one
of the Offline menu appears.
5. Press
F2-Initialize to enable the new parameter settings.
PARAM ENTRY . . .
CHG PARAM
SAVE PARAM
LOAD DEFAULT
EXIT
OFFLINE . . .
ONLINE
PAPER ADV
INITIALIZE
ORIGIN