2.3.20. COIL SETUP
This procedure is used to calibrate the knife and pen pressures, and to set the
knife and pen “landings.”
After calibration, the values are saved in the system’s non-volatile RAM.
A tension gauge of ± 100 gr. and ± 500 gr. is required to execute this test.
The desired pressure appears in the upper line of the display. The bottom line of
the display indicates the value that has to be sent to the head in order to
reach the desired pressure (this value is between 0 and 127). Press the
key to begin the test and then follow the instructions on the LCD screen.
CAUTION
Do not perform the coil test when the machine is working
properly. Changing the parameters to incorrect values may
seriously affect cut quality and even damage the cutter.