background image

P.14

P.15

If the connection cable is damaged, it must be replaced with an original spare cable from the manufacturer by 

an authorised technician in order to avoid any hazards.

If you cannot rectify the fault with the aid of the troubleshooting table, please contact the customer service.

The following table will help you to determine and rectify the reasons for possible problems.

5. Troubleshooting

Problem

Possible cause

Remedy

No water flows

Water supply is turned off

Open the main water valve and angle valve

Water flows more slowly 

than expected

Water pressure too low

Check the water flow pressure 

Dirt in the pipes

Remove any dirt from the filter, angle valve 

and tap

The appliance switches 

itself on and off

Water pressure fluctuates,  

flow rate is too low 

Remove any dirt / increase the water flow 

pressure, close other taps, open angle 

valve further

Water remains cold even 

though the appliance 

switches on

Electric supply incorrect

Check the electric supply

No voltage

Check fuses in the electrical installation

Faulty heating element

Replace heating element (by authorised 

technician)

Appliance does not 

switch on and the water 

remains cold

Water connections mixed up

Check installation

Water flow pressure too low

Check water flow setting (by authorised 

technician), open angle valve further, 

check water pressure

Dirt in the pipes

Remove dirt from the inlet and outlet pipes

Hot water temperature 

varies

Water pressure fluctuates

Stabilise the water flow pressure 

Supply voltage varies

Check the supply voltage

Hot water temperature is 

too low

Flow rate is too high or inlet tem-

perature is too low

Adjust the water flow (by authorised

technician)

Power supply is too low

Check the power supply

GPI-M6:A faulty heating element

Replace heating element (by authorised 

technician)

4.4 Purging

       Each time it is emptied (for example after work on the plumbing system or following repair work on the  

       appliance), the instantaneous electric water heater must be purged before it is used again.

       

       1. Switch off the power supply to the instantaneous electric water heater.

       

       2. To purge the instantaneous electric water heater, open the hot water tap and wait until the water 

           emerges free of air bubbles.

        

       3. Switch the power supply back on again.

4.5 Cleaning and maintenance

-  Plastic surfaces and fittings should only be wiped with a damp cloth. Do not use abrasive or chlorine-

based cleaning agents or solvents.

-  For a good water supply, the outlet fittings (special tap aerators) should be unscrewed and cleaned at 

regular intervals. Every three years, the electrical and plumbing components should be inspected by an 

authorised professional in order to ensure proper functioning and operational safety at all times.

4.3 Changing the strainer

The cold water connection of the instantaneous electric water heater is equipped with a strainer. Dirt depos-

ited in this strainer can reduce the hot water output. Clean or replace as follows.

1. Switch off the power supply to the instantaneous electric water heater.

2. Close the shut-off valve in the inlet pipe.

3. Disconnect the water pipe from the water inlet. The water inlet is indicated in blue on the rating plate 

    (under the cover). This can cause water leakage.

4. Lever the strainer out of the connection piece of the   

    instantaneous electric water heater and clean or 

    replace it.

5. Insert the clean strainer into the connection piece 

    and connect the water pipe to the water inlet of the  

    instantaneous electric water heater.

6. Purge the instantaneous electric water heater as 

    described in the chapter “Purging”.

7. Switch the power supply back on again.

4. Use

Summary of Contents for GPI-M6

Page 1: ...ructions and warranty information carefully before use and keep them handy for future reference Online Warranty Registration U S E R M A N U A L WH GPI M6 M 18 6 Printed in Germany GPI M6 Instantaneous Electric Water Heater ...

Page 2: ...appliance and for the end user The latest version of the instructions can be found online at www germanpool com 1 2 Safety instructions Do not use the appliance until it has been correctly installed and unless it is in perfect working order Do not remove the front cover under any circumstances before switching off the mains electrical supply to the unit Never make technical modifications either to...

Page 3: ...at any time The required water resistance may not fall below the value stated on the rating plate at any time To observe additionally for pressureless installation The water outlet behind the devices must not be blocked and the water flow must not be restricted The water outlet facilities jet control and other outlet unit must be decalcified regularly Deposits must be removed in regular intervals ...

Page 4: ... PE 220 V AC Nominal power rating 6 0 kW Nominal current 27 3 A Hot water flow rate at t 25 K 1 3 4 l min Switching on at 2 2 l min Minimum required cable size 4 0 mm2 Approx weight filled with water 1 5 kg Product dimensions Height Width Depth 13 5 18 6 8 7 cm Connecting type pressure resistant pressureless Heating system IES Bare wire heating system VDE approv Protec class VDE IP25 The declarati...

Page 5: ...equired If nevertheless a non return valve has to be installed it may only be placed in the hot water outlet line behind the instan taneous water heater The minimum requirements for the required water resistance must be complied with The required water resistance of the can be obtained from your water supply company 3 Installation 3 1 2 Pressure resistant closed outlet installations Angle valve ou...

Page 6: ...the cover d Dismount the pre installed connection cable e Route the permanently installed cable through the grommet and connect it as shown in the circuit diagram Make sure that the grommet fits tightly around the cable to ensure optimal protection against water f Refit the cover on the appliance The earth conductor must be connected Circuit Diagram 3 Installation 3 3 Water connection 1 Position t...

Page 7: ...er heater open the hot water tap and wait until the water emerges free of air bubbles 2 Switch on the electric power 3 Adapt the water flow if necessary if for example the temperature is not reached The procedure is described in the chapter Use 4 Explain the functions and use of the instantaneous electric water heater to the user and hand over this User Manual to the user for information and futur...

Page 8: ...he power supply GPI M6 A faulty heating element Replace heating element by authorised technician 4 4 Purging Each time it is emptied for example after work on the plumbing system or following repair work on the appliance the instantaneous electric water heater must be purged before it is used again 1 Switch off the power supply to the instantaneous electric water heater 2 To purge the instantaneou...

Page 9: ...valve in the inlet pipe 3 Disconnect the electrical connection in the appliance junction box or disconnect the protective earth plug if the appliance is fitted with a plug 4 Disconnect the water pipes from the connectors of the appliance This can cause water leakage 5 Remove the appliance from the wall bracket To do so insert the tip of a wide screwdriver as far as it will go into the latch betwee...

Page 10: ...5 符合歐盟法規No 812 2013的初步要求 1 有關水電阻值詳情可向水務署查詢 2 溫度上升 例如15 40 產品規格及設計如有變更 恕不另行通知 中英文版本如有出入 一概以英文版為准 本產品使用說明書以 www germanpool com 網上版為最新版本 正常情況下 如供水系統之來水水壓超過0 6 MPa 用戶必須額外加裝減壓器將水壓調低 如來水 壓力超過0 6 MPa而用戶未有安裝減壓器 本公司有權拒絕為熱水器進行任何維修 目錄 1 1 1 1 2 2 2 1 2 2 2 3 3 3 1 3 1 1 3 1 2 3 2 3 3 3 4 3 5 4 4 1 4 1 1 4 1 2 4 2 4 3 4 4 4 5 5 6 6 1 6 2 重要說明 使用本說明書 安全指示 產品描述 技術規格 尺寸 包裝內容 安裝說明 一般安裝方式 使用特殊開口水龍頭的排氣安裝方式 使用加壓熱水器專...

Page 11: ... 141 87 25 30 150 即熱式電熱水器 螺絲及壁塞 使用說明書 掛接背板 使用特殊開口水龍頭的排氣安裝方式 單位 毫米 接駁喉咀G 接駁喉咀離地約550毫米 盤面離地約850毫米 133 22 75 186 70 電源接駁位 電源線進口約553毫米 135 掛牆孔離地約520毫米 3 安裝說明 本設備的安裝 初始操作和維護只能由經過授權的專業人員進行 他們將負責遵守適用的標準和安裝規 定 我們對由於不遵守這些說明而導致的任何損壞概不負責 3 1 一般安裝方式 3 1 1 使用特殊開口水龍頭的排氣安裝方式 ...

Page 12: ...閥也可正常運作 如安裝時需使用止逆閥 必須將其安裝在即熱式電熱水器後方 的熱水出水管線中 來水電阻必須符合最低要求 最低來水電阻可從供水公司查詢 3 3 連接水管 1 安裝熱水器時 供水接頭必須垂直朝上或朝下 直接連接瓷盤水龍頭 2 使用螺絲和尺寸適中的壁塞固定掛接背板 3 將熱水器置於掛接背板上 再將其卡入定位 熱水器必須正確裝妥於掛接背板 否則不可操作 a 密封墊 b 濾網 c 冷水接管 入水 d 熱水接管 出水 e 銘牌外蓋 6 避免水管等零件對熱水器施加負重壓力 7 安裝完畢後 開啟熱水水龍頭 仔細檢查所有連接處是否有滲漏情形 8 建議安裝一個合適的噴水調節器 如有需要可替換現有老舊的調節器 安裝掛接背板 4 連接水管前 請以清水將水管徹底沖洗乾淨 5 連接水龍頭 冷水入水管 藍色 和熱水出水管 紅色 均標示於銘牌上 銘牌位於外蓋下方 3 安裝說明 3 1 2使用加壓熱水器專用水龍...

Page 13: ...方毫米 c 打開前蓋 d 卸載預先裝好之電線 e 把用作永久安裝之電線穿過電線封套並把電線如電路圖所示連接 確保電線封套緊密包裹電線 周圍 以達到最佳防水保護 f 裝回前蓋 請務必接上接地線 電路圖 3 安裝說明 3 5 初始使用 此時切勿打開電源 1 打開熱水水龍頭 讓水流出直到沒有氣泡為止 2 打開電源 3 設定所需的出水溫度 如果無法達到理想溫度或有其他問題 請調整水流量 此步驟請參閱 使用方式 章節 4 向使用者解釋熱水器的功能及使用方式 並將使用說明書交給用戶作日後參考之用 熱水龍頭打開時 熱水器自動啟動 關閉熱水水龍頭 熱水自動關閉 4 1 銘牌掩冚 掩冚內側會註明熱水器類型名稱 1 序號 2 以及貨號 3 4 1 1 拆下掩冚 銘牌和外蓋螺絲皆位於此掩冚內 1 按住皺摺處將掩冚朝掛接背板方向推 2 按住後方的兩個角落 將掩冚向下壓 直到前端向上翹起 3 向外拉出即可拆下掩冚 ...

Page 14: ...冷水連接件 重新連接水管到 即熱式電熱水器的入水口 6 根據 排氣 章節內容為熱水器排氣 7 再連接電源 4 使用方式 40 30 25 20 10 0 0 0 1 0 2 0 熱水輸出 l min 溫度上升 K 3 0 4 0 5 0 4 4 排氣 為避免損壞本熱水器 第一次使用前 進行供水系統維修後或後續維修後必須先排空熱水器中的空 氣 才能再度使用熱水器 1 關閉熱水器的電源 2 開關熱水水龍頭 直到水管不再排出任何空氣 而且熱水器內部的空氣全數排空為止 3 完成此步驟之後 才能開啟熱水器電源 4 5 保養與維護 請一律使用濕布擦拭本熱水器和配件 請勿使用具侵蝕作用或含氯的清潔劑或溶劑 堆積在水管和熱水器中的污物和水垢會影響熱水器功能 如果水流量變小或出水時發出雜音 表 示可能堆積了過多的污物和水垢 此時需請技術人員檢查熱水器 如有必要則需清潔冷水入水口 的濾網 4 使用方式 4 1...

Page 15: ...查電源供應 沒有電壓 檢查斷路器 發熱線損壞 更換發熱線 需由合格技術人員進行 熱水器沒有啟動 水溫 沒有升高 水管連接錯誤 檢查入水口和出水口的安裝 水壓不足 檢查水壓 檢查水流調整情形 將止水閥 開得更大 需由合格技術人員進行 水管中有污物 清掉濾網 水閥和水龍頭的污物 熱水溫度忽高忽低 流量忽高忽低 令流量變得穩定 電壓不穩定 檢查電壓 熱水溫度太低 水流量太大或入水水溫過低 調整水量 需由合格技術人員進行 電壓太低 檢查電源 6 1 拆卸 1 關閉即熱式電熱水器電源 2 關閉入水管的截流閥 3 切斷接線盒的供電電源 如熱水器帶有電源插頭 切斷保護接地插頭 4 把水喉從進水口中解開 此步驟可能會導致漏水 5 將熱水器從掛接背板取下 將平頭螺絲批子尖端插入水管連接之間的交界處 直到盡頭 輕壓螺絲 批子使其朝上方翹起 將熱水器傾斜 不超過15 朝上拆下熱水器 6 把掛接背板卸下 5 常見...

Page 16: ...忽使用本 機所引致之損壞 3 於下列情況下 用戶之保用資格將被取消 購買發票有任何非認可之刪改 產品被用作商業或工業用途 產品經非認可之技術人員改裝或加裝任何配件 機身編號被擅自塗改 破壞或刪除 4 總代理有權選擇維修或更換配件或其損壞部份 5 產品一經被轉讓 其保用即被視作無效 機身號碼 Serial No 購買商號 Purchased From 發票號碼 Invoice No 購買日期 Purchase Date 型號 Model No 另請填妥以下表格並與正本發票一併保存 以便維修時核對資料 用戶提供之所有資料必須正確無誤 否則免費保用將會無效 Please fill out the form below This information and the original purchase invoice will be required for any repairs Warran...

Page 17: ... 3 F Edificio Industrial Pou Fung 145 Rua de Francisco Xavier Pereira Macau Tel 853 2875 2699 Fax 853 2875 2661 Macau All rights reserved Copying reproducing or using the contents of this manual is not allowed without prior authorization from German Pool violators will be prosecuted HONG KONG TOP BRAND TEN YEAR ACHIEVEMENT AWARD 2015 2005 2008 2007 2008 2007 2015 2014 2015 2015 Subject to technica...

Reviews: