重要說明

為安全起見,初次使用產品前請先細閱本說
明書,並保存說明書,以便作參考之用。

本產品只供家居使用。請必須依照本說明書
內的指示安裝及操作。

1. 本產品並不適用於兒童、身體或心智殘障、

 

   缺乏經驗或知識的人士使用和玩樂,除非

 

   該人士得到負責保障其安全的人士的監管

 

   或指引。

2. 請將產品遠離兒童。不要讓兒童單獨使用

 

   本產品。

3. 為免發生危險,若發現電源線有任何損壞,

 

   必須停止使用產品,並立即聯絡本公司或

 

   合資格技術人員進行更換。

4. 清潔、維修或拆除抽油煙機前應先切斷

 

   電源。

5. 電源插座必須安裝接地線。

6. 請接駁獨立排氣喉將油煙排往室外。  

7. 抽油煙機不可與燃氣或使用其他能源之

 

   器具共同使用同一排放管道。

8. 抽油煙機安裝於氣體爐上方時,抽油煙

 

   機底部距離爐面700±50mm之間為宜。

9. 切勿在抽油煙機下直接燃點明火。

注意事項

 

Notice Before Use

Important

For safety purpose, you should read the 
instructions carefully before using the 

appliance for the first time. Save the 

instructions for future reference.

The appliance is designed for domestic use 
and may only be installed and operated in 

accordance with these instructions for use.

1.  The appliance is not intended for the use 

of, and playing with, by persons (including 

children) with reduced physical, sensory or 

mental capabilities, or any individual lack of 

experience and knowledge, unless they have 

been given supervision or instruction.

2.  Keep children away from the appliance 

Do not let them use the appliance without 

supervision.

3.  If the power supply cord is damaged, do not 

operate the appliance. Contact German Pool 

or licensed technician for a replacement 

immediately.

4.  Disconnect the power supply before cleaning, 

repairing or dismantling the range hood.

5.  The range hood must be earthed.

6.  Connect the range hood with an independent 

air vent to exhaust lampblack.

7.  The air must not be discharged into a venting 

pipe that is used for exhausting fumes from 

appliances burning gas or other fuels.

8.  The appliance should be positioned 

700±50mm above the cooking range. 

9.  Do not flambe under the range hood.

Summary of Contents for TOS-723D

Page 1: ...P 1 TOS 723D TOS 923D Wall Mount Range Hood...

Page 2: ...P 2 Please register your warranty information now For Warranty Terms Conditions please refer to the last page of these operating instructions...

Page 3: ...e 04 Product Structure 06 Installation Instructions 07 Wiring Diagram 08 Operating Instructions 09 Troubleshooting 10 Care Maintenance 11 Fluorescent Lamp Replacement Procedures 13 Technical Specifica...

Page 4: ...owledge unless they have been given supervision or instruction 2 Keep children away from the appliance Do not let them use the appliance without supervision 3 If the power supply cord is damaged do no...

Page 5: ...ease vapor will be exhausted through the air vent when the range hood is in operation Only very little amount of residual oil will be collected in the Oil Collecting Tray 13 There should be adequate v...

Page 6: ...P 6 Product Structure 1 2 3 4 5 6 1 Light Bulb 2 Control Panel 3 Oil Collector Small 1 pair 4 Bottom Cover 5 Fan 1 pair 6 Oil Collector 1 pair 5 6 3 4 1 2...

Page 7: ...s near 700mm results in higher venting efficiency Fig A Length of Exhaust Pipe The length of the exhaust pipe should be minimized to avoid air turbulence inside the pipe Fig B Keep the Hood Level The...

Page 8: ...TURBO SPEED ON OFF SAFETY SWITCH Motor Motor CAPACITOR YELLOW YELLOW BROWN BROWN YELLOW BROWN WHITE RED BLUE GREY YELLOW BROWN WHITE RED BLUE GREY WHITE BLACK LIGHT BULB BLUE GREY GREY BLUE GREEN BROW...

Page 9: ...in the room when a gas cooking range or other fuels are in use for cooking 3 The air from the range hood must not be discharged into a venting pipe that is used for exhausting fumes from appliances bu...

Page 10: ...epair or replace Repair or replace The hood vibrates Not firmly mounted Not installed securely Impeller is damaged and becomes imbalanced Secure the hood Secure the motor Repair or replace Fan works a...

Page 11: ...Clear oil from oil collectors when they are more than half full of grease in order to avoid spilling Warning There is a risk of fire if the repair and cleaning of the range hood especially the fan an...

Page 12: ...se 4 Loosen the locking caps by turning the caps clockwise and take out the turbine impellers 5 Use a soft cloth to clean the inner and outer surfaces with a mild liquid detergent and then rinse the t...

Page 13: ...out as shown in the following 2 Push the lamp cover in as shown in the following 3 Take the damaged Fluorescent Lamp by rotating in anti clockwise direction 3 Fasten the lamp cover screw by screw driv...

Page 14: ...RPM Max 2300 50 RPM Max Exhaust Flow 1000 m h 1000 m h Dimensions H 165 mm W 895 mm D 545 mm H 165 mm W 710 mm D 545 mm Exhaust Outlet Diameter 152 mm 152 mm Net Weight 13 3 kg 12 3 kg Specifications...

Page 15: ...ill in its discretion repair or replace any defective part 5 This warranty will be void if there is any transfer of ownership from the original purchaser Service area includes Hong Kong Island Kowloon...

Page 16: ...secuted Hong Kong Sole Agent China Sole Agent Tel 852 2773 2888 Fax 852 2765 8215 116 2 113 Room 113 Newport Centre Phase II 116 Ma Tau Kok Road Tokwawan Kowloon Hong Kong 3 F Takshun Plaza Nanguo Eas...

Reviews: