1. TECHNICAL SPECIFICATIONS

 

Supply kits suitable for the DIESEL transfer, composed of:

 

- Steel chassis

 

- Self-suction pump

 

- Mechanical meter

 

- 4 m hose 
- Nozzle 
- Noise level: L

EQA

 < 85 dBA (1 m) 

Please see the enclosed manuals to consult the technical specifications of each kit component.

 

 

ATTENTION: Please take into account the flow of the supply kit is lower than the pump one 
because of the charge losses caused by the own supply kit (nozzle, hose, adapters and so 
on).

 

  COMPACT size (approx.): 380x345x360 mm (length x width x height) 

  COMPACT weight: 22 kg (approx.)

 

  TOTEM size (approx.): 385x435x1,500 mm (length x width x height) 

  TOTEM weight: 48 kg (approx.)

 

 

 

2. WARNINGS

 

INSTALLED PUMP 

FLOW (l/min)* 

The main aim of this manual is to advise the users how to make the kit installation and location, 
how to use it and how to maintain adequately.

 

IRON-50 230 V 

40-50 

Please read all the instructions carefully before using the product. The people who do 
not know the instructions must not use it.

 

* Real COMPACT and TOTEM flows 

This manual describes how to use the machine according to the project hypothesis, the technical features, the types of installation, the use, the 
maintenance and the training regarding to possible dangers.

 

The instruction manual must be considered as a part of it and keep it for future inquiries during all its working life. We suggest keeping it in a 
dry and protected place. 

The manual reflects the technical situation at the moment of the kit sale and cannot be considered inadequate for the reason of being updated afterwards 
according to the new experiences. The manufacturer is keeping the right to update the production and the manuals without being forced to update the 
production and previous manuals. 

 

3. SECURITY INSTRUCTIONS

 

To use the supply kit without suffering any danger, it is essential to read and follow each and every one of the following warnings and cautions:
3.1. PLEASE FOLLOW ALL THE INSTRUCTIONS CAREFULLY. The supply kit must be connected adequately up the ground and use suitable cables 
and pipes. 
3.2. The broken down supply kits must be repaired in an authorized workshop or in our factory. 
 

 

3.3. ATTENTION 
Do not smoke near the kit or use it near a flame. This can cause an explosion and even the death.

 

 

3.4. It is advisable to install a filter in the suction to avoid solid impurities sinking in the pump and/or the meter. The absence of these impurities 
means the long-life of the supply kit. 

ATTENTION: If the hose and the nozzle are out in the open, in summer weather and/or in very hot countries, after the refuelling (once the supply kit is 
stopped), we recommend you to open the nozzle to purge the stored up pressure in the hose. 

Summary of Contents for Compact 50M-230

Page 1: ...ding to possible dangers The instruction manual must be considered as a part of it and keep it for future inquiries during all its working life We suggest keeping it in a dry and protected place The m...

Page 2: ...must be fixed by 4 point with M8 screws with its own washers Please see the drawing COMPACT MSGM KIT FIXATION The COMPACT must be fixed in a pedestal or wall support with M6 screws The hole placing de...

Page 3: ...be determined whether the responsibility is from the manufacturer the user the installer or the delivery transport 3 The warranty does not cover Inadequate use negligence corrosion abuse manipulation...

Page 4: ...21 IRON 50 230 V PUMP BODY 003503002 11 3 m 230 V CONNECTION CABLE WITH INJECTED PLUG 800900010 TECHNICAL SPECIFICATIONS IRON 50 230 V pump of grey foundry with filter built in Self suction Eccentric...

Page 5: ...s of dirt in filter problem in suction line or in delivery the bypass is blocked blade friction blade or roller wear dirtiness on the red adaptor disassemble and clean the filter verify suction line t...

Page 6: ...2 MEASURING BOX SUPPORT 320002006 15 M 5x22 DIN 912 SCREW 805400008 33 GEAR MEASURING UNIT PINION 320002005 16 RESET DRIVE 320005001 34 D 7 x D 4x6 SLEEVE 320004016 17 D 4 2x9 5 DIN 7981 ZINC PLATED S...

Page 7: ...ted 2 4 To make this operation take out the plug 4 and turn the screw 6 clockwise Then the flow percentage decreases If you turn it anticlockwise it increases A complete turn varies the measurement mo...

Reviews: