Technical data for the plumbing system:
- Working pressure: recommended operating field 2 ÷ 4 bar
- Maximum working pressure: 5 bar (Install a pressure reducer for higher hydraulic pressures)
- Maximum working temperature: 65°c
- Floor waste required with capacity ≥ 40 l/min.
- 13,6 kg empty weight of the complete head shower (with water about 16,1 kg)
Data for plant dimensioning
Supply pipe to shower head [ A ]: minimum internal diameter 12mm
Static
pressure
[ bar ]
Minimum required feeding
for a correct working of the shower system*
[ l/min ]
2
26,5
3
21,5
4
19,5
5
19
( * ) Minimum delivery from head shower for the correct working “Rain”: 16 l/min [ B ].
Data for boiler and waste dimensioning
Static
pressure
[ bar ]
Maximum delivery for the shower system
fed with internal 12 mm Ø pipes
Rain Function [ B ]
[ l/min ]
2
19 [ with limiter ]
3
19 [ with limiter ]
4
19 [ with limiter ]
5
19 [ with limiter ]
Dati tecnici - Technical data - Données techniques - Technische Eigenschaften -
Datos técnicos - Технические данные