Enhanced Network Security
94
5
E
Press
[
Invalid
]
for the protocol you want to disable.
F
Press
[
OK
]
.
G
Press the
{
User Tools/Counter
}
key.
Reference
Advanced network settings can be specified using Web Image Monitor.
For details, see the Web Image Monitor Help.
Access Control
This can be specified by the network administrator.
The machine can control TCP/IP access.
Limit the IP addresses from which access is possible by specifying the access
control range.
For example, if you specify the access control range as
[
192.168.15.16
]
-
[
192.168.15.20
]
, the client PC addresses from which access is possible will be from
192.168.15.16 to 192.168.15.20.
Limitation
❒
Using access control, you can limit access involving LPD, RCP/RSH, FTP, IPP,
DIPRINT, Web Image Monitor, SmartDeviceMonitor for Client or DeskTop-
Binder. You cannot limit the Monitoring of SmartDeviceMonitor for Client.
❒
You cannot limit access involving telnet, or SmartDeviceMonitor for Admin,
when using the SNMPv1 monitoring.
A
Open a Web browser.
B
Enter “http://(machine's-address)/” in the address bar to access the machine.
C
Log onto the machine.
The network administrator can log on using the appropriate login user name
and login password.
D
Click
[
Configuration
]
, click
[
Security
]
, and then click
[
Access Control
]
.
The
[
Access Control
]
page appears.
E
In
[
Access Control Range
]
, enter the IP addresses from which access to the ma-
chine is permitted.
D0086951_RussianC45-EN.book Page 94 Wednesday, May 31, 2006 11:45 AM