background image

X

Y

Digital Conference System

EG-6620

USER MANUAL

Summary of Contents for EG-6620

Page 1: ...X Y Digital Conference System EG 6620 USER MANUAL ...

Page 2: ...11 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provide plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 12 Protect the power co...

Page 3: ...arked with the WEEE symbol this indicates that this product must NOT be disposed of with other waste Instead it is the user s responsibility to dispose of their waste electrical and electronic equipment by handing it over to an approved reprocessor EC Declara on Of Conformity USER MANUAL EG 6620 Digital Conference System We the company E C TONG ELECTRONICS CO LTD declare under our responsibility t...

Page 4: ...phones via extension 01 Before you start Introduc on 1 Features 1 Product overview Controller front panel 2 Controller rear panel 2 Chairman unit 3 Delegate unit 3 System connec on diagram 4 Opera on Controller system interface 5 CONFERENCE CONTROL Queue mode 6 Meet mode 7 Meet setup 7 Chairman setup 8 Control unit 8 Volume 9 CAMERA TRACKING Camera tracking 10 Camera control 10 Setup preset 11 REC...

Page 5: ...ule Detachable design to pickup audio signal from speaker 2 Mic indicator To indicate the working status of microphone 3 Built in speaker Speech signals from other microphone unit and from controller are output from this speaker 4 Mic On Off key 5 Volume control The volume control of built in speaker headset 6 Display 6 USER MANUAL EG 6620 Digital Conference System Controller Front Panel 1 USB reco...

Page 6: ...n SYSTEM SETUP To configure the basic info the system such as IP add me host ID etc QUICKMARK QR code which allows operator to access the web management system easier RESTART To reboot the system System connec on diagram Note Microphone units ID are set in factory but users can reset the ID for each microphone a er the installa on Please ensure the system is running by required power supply Avoid u...

Page 7: ...ain OPEN MIC qty this pa ern applied to delegate units For instance OPEN MIC qty is 2 the 1st ac ve unit will be switched off when 3rd unit switched on LIFO Last in first out under certain OPEN MIC qty this pa ern applied to delegate units For instance OPEN MIC qty is 2 the 2nd ac ve unit will be switched off when 3rd unit switched on SOUND CONTROL ON OFF To allow delegate to open the microphone unit...

Page 8: ...ence control Volume LINE IN OUT To adjust the audio level of input output SOUND CONTROL To adjust sensi vity of voice ac va on func on BUZZER MUTE To enable or disable the buzzer of the controller UNIT LOUDSPEAKER To adjust volume of speaker of all microphone units UNIT LOUDSPEAKER MUTE Speakers on the units will be muted when this is on CERTAIN UNIT OFF ON To switch on off specific microphone unit ...

Page 9: ...e tracking preset configured correctly DELETE PRESET To delete all the presets saved FREEZE This func on enables image freeze during the camera movement VIEW PRESET To allow user to check the presets saved UNIT LIGHT ON OFF To lit the indicator on the microphone to assist operator to iden fy the unit on opera on USER MANUAL EG 6620 Digital Conference System 10 Camera tracking CAMERA SETUP Camera pr...

Page 10: ...recording func on user can record replay through this window Support thumb drive capacity in FAT 32G file format MP2 128Kbps System setup SETUP IP ADDRESS To define the IP for accessing web management system HOST CONNECTION MODE To enable or disable the extension connec on RESTORE TO PRESET The system will be restored to factory se ng TIME To configure the system me SETUP ID The ID assigned to contro...

Page 11: ... only to define the qty of delegate unit can open MEETING MODE Discussion camera tracks to the last switched on microphone unit Auto camera tracks to microphone unit which received voice signal Chairman Only chairman unit can be switched on All On All microphone units can be switched on no limit on OPEN MIC qty USER MANUAL EG 6620 Digital Conference System 14 Login page Web management system is the...

Page 12: ...erence System 16 MUTE AUTO OFF To switch off the microphone when no voice signal pickup in set me frame 0 S means this setup is disable SIGN IN SELECT op onal This op on available with system with vo ng func on user can choose either cardless sign in or card sign in to enable the system to calculate the no of a endee before the kick off of vo ng LINE IN OUT VOL The main volume control of system UNIT...

Page 13: ...Video switch RS 232 X 1 Camera RS 232 X1 12P Terminal block Audio input RCA X 1 Audio output XLR X 1 RCA X 1 PC USB X 1 Audio recording USB X 1 Ethernet RJ45 X 1 483 x 323 x 90mm 5 5kg Black Tel out 15dBV Line out 0dBV BAL out 4dBV USER MANUAL EG 6620 Digital Conference System 18 Setup system SETUP SYSTEM interface allows operator to setup the me and IP address of the system user should reboot the...

Page 14: ...x 1 The specifica ons are correct at the me of prin ng this manual For improvement purposes all specifica ons for this unit including design and appearance are subject to change without prior no ce USER MANUAL EG 6620 Digital Conference System 20 Microphone unit EG 6620C EG 6620D Power supply Working current Cartridge Pa ern Sensi vity Frequency response SNR Dynamic range Harmonic distor on Input im...