15
Zones
Zone
Description
1
Loading: Stopped by emergency stop and safety stop. Stops all
pneumatic equipment except for the robot gripper.
2
Unloading: Stopped by emergency stop and safety stop. Stops all
pneumatic equipment except for the robot gripper.
3
Buffer: Stopped by emergency stop and safety stop. Stops all
pneumatic equipment except for the robot gripper.
Working methods in case of problems or breakdown
Interventions in case of problems and rectification, troubleshooting.
Contact your local maintenance, otherwise contact Evomatic AB.
Removal of personnel
See security information from robot supplier (ABB), will be included in the supplied
documentation from Evomatic.
Look for Section Safety information
Chapter- Emergency safety information – Operating manual ESI.
See chapter 1.4 Releasing a person trapped by the robot arm.
8
Zon3 Gate 2
3F7SG2
Haake key back in
original place
Gate used for access robot cell
9
Light barrier
100SG1
Outside, other zone
1A2S2, 2AS2
Protection between Zone 1 and 2.
Only active when 1 of the zones is
turned off
Summary of Contents for GEV TS 121650 AR-2
Page 1: ...1 GEV TS 121650 AR 2 PFIZER ROBOTIC SYSTEMS 0011393179 010 USER MANUAL...
Page 49: ...49 Robot pendant Manual Auto mode Auto Manual mode Quick menu Key selector...
Page 52: ...52 Quick select Jogging Increments Motion mode Step mode...
Page 54: ...54 Robot 210 Home position Robot 220 Home position...