78
Faults and troubleshooting
Gewiss
Code
Error description
Solution
Position
Error 9
The I/O remote control is no
longer communicating with
the electronic card
Check the Modbus
line connection
Check the power supply to the
I/O remote control
Check the I/O remote control
is working properly
Make sure the component
on the Modbus line is
numbered correctly
Error 10
The station has been OFFLINE
for >24h
Try to restart the station by
disconnecting the power supply
for at least 3 minutes and then
reconnecting it
If the station remains in this
condition, check the connection.
Contact your aftersales service
Error 11
The contactor is working when
it shouldn't be. The Schuko
socket-outlet is powered in the
standby condition
Check the signal from the
electronic board to the
contactor, to make sure
the former isn't controlling
the latter. If the board isn't
controlling the contactor, make
sure the contactor contacts
aren't jammed.
If necessary, replace the device.
7.55.4.515.2 - Installation and Operation Manual
Summary of Contents for JOINON
Page 2: ......
Page 4: ...4 Gewiss 7 55 4 515 2 Manuale d installazione e uso ...
Page 46: ...46 Gewiss 7 55 4 515 2 Installation and Operation Manual ...
Page 88: ...88 Gewiss 7 55 4 515 2 Manuel d installation et usage ...
Page 130: ...130 Gewiss 7 55 4 515 2 Manual de instalación y uso ...
Page 172: ...172 Gewiss 7 55 4 515 2 Handbuch für Montage und Betrieb ...
Page 214: ...214 Gewiss 7 55 4 515 2 Manual de instalare și utilizare ...
Page 256: ...256 Gewiss 7 55 4 515 2 Használati és karbantartási kézikönyv ...
Page 298: ...298 Gewiss 7 55 4 515 2 Installatie en gebruikshandleiding ...
Page 340: ......