Product Specifications and Usage Information 

P4400 

GENESYS 30 Spectrophotometer 

 

PRODUCT PHOTO 

 

                                                        Thermo Scientific GENESYS 30 Spectrophotometer 

Included Components: 

 

Plastic insert plate with cuvette holder 

 

USB thumb drive 

 

Power cord 

 

USB interface cord 

Packaging: 

Unit is shipped in a cardboard box with a form-fitting foam enclosure. 

Storage: 

Store the instrument in a cool and dry location. 

INSTALLATION 

Please refer to the 

Thermo Scientific GENESYS 30 Spectrophotometer User Guide 

for explicit detail.  Information supplied herein 

should be considered supplemental or redundant and is specific to usage for dosimetry in radiation processing applications. 

CAUTION!

  - Whenever the spectrophotometer has been stored or shipped, immediate exposure to room air can cause 

condensation damage.  Move the shipping cartons to the installation location at least 24 hours before installation.  This allows 

the instrument to equilibrate at room temperature before the shipping cartons are opened and protective packaging is 

removed.  

Unboxing:

 

After at least 24 hours, open the shipping box and remove the documentation packet and USB thumb drive.  Remove the 

instrument from its shipping box. 

Operating Environment: 

Instrument was designed for use under the following conditions: 

 

Temperature Range* 

5°C to 35°C (41°F to 95°F) 

Relative Humidity 

<20% to 80% noncondensing 

Altitude 

0m to 200m 

 

*Operating the instrument outside of this temperature range may cause permanent damage. 

Summary of Contents for P4400-EU

Page 1: ...Physical Specifications GEX Part No Description Product Dimensions Packaging Dimensions Product Weight P4400 US Spectrophotometer Type B plug 34 3 cm L x 38 1 cm W x 20 3 cm H 13 5 L x 15 W x 8 H 58 4...

Page 2: ...ge for dosimetry in radiation processing applications CAUTION Whenever the spectrophotometer has been stored or shipped immediate exposure to room air can cause condensation damage Move the shipping c...

Page 3: ...with the 2 5mm aperture film holder or any dosimeter sample in the sample compartment simply turn the unit off clear the obstruction and turn the instrument power back on 6 The instrument will perfor...

Page 4: ...ment is installed at the user s site The term Performance Verification replaces the older term Calibration Verification but the intent of either is the same to determine if the instrument is performin...

Page 5: ...range of wavelengths is the objective in particular for qualification and performance verification activities and this can be accomplished using the Scan feature of the GENESYS 30 Follow the procedure...

Page 6: ...col is subject to change without notice Users are ultimately responsible for validation of their systems GEX does not provide any warranty of any kind regarding this procedure IQ OQ PQ for use in B3 o...

Page 7: ...ntained and cared for will perform better and have a longer life Complete cleaning instructions which include the proper materials can be found in the GENESYS 30 User Guide Instructions for cleaning t...

Page 8: ...mm x 15mm GEX DoseStix style film dosimeters in the sample compartment for measurement P4420 WINdose Dosimeter holder Positioning 10mm x 10mm film dosimeters in the sample compartment for measurement...

Page 9: ...ar from the date of delivery for any customer dissatisfaction REFERENCES DOCUMENTS Thermo Scientific documents typically included with each instrument purchase GENESYS 30 User Guide GENESYS 30 Setup G...

Reviews: