www.geyserwise.co.za
31
IMPORTANT:
Ensure that the circuit breaker is off when making connections. Once all connections are made switch the
circuit breaker on.
Connection Diagramme
Geyserwise MPPT Controller (Ensure that 4mm Solar Cable is used) (Use Cables as Supplied)
Battery
3
–
LDR – outside
Set voltage
on MPPT
250W PV
panel
250W PV
panel
1
2
1
CN5C
RT
GeyserWise control
Thermostat
PTC element
White DC
Blue DC
Black AC
Red AC
+
–
+
–
4
4
0
1
Isolator switch
L1 N1
G
L2 N2
+
PV Bat
Pump
Ground