Device safety test and production test

Device safety test and production test

WARNING 

Risk of fatal injury due to electric shock!

 

X

The electrical system (230 V/115 V) may only be connected and disconnected by a professional electrician  

or specialist electrical technician.

 

X

Complete a device safety test according to EN 60335-1 Annex A.

The device safety test consists of the following parts:

 

à

Protective earth test with 10A test current

 

à

Insulation strength testing (high voltage test) with 1000 VAC 

A testing device suitable for this standard must be used.

Testing process

 

X

Connect the mains cable with the mains plug to the transformer.

 

X

Insert the mains plug in the testing device.

 

X

Start the test on the testing device.

 

X

Use the probe to test all metal parts connected to the protective conductor in sequence. 

The low ohm connection between the PE line of the mains cable and the metal part contacted with the probe 

is tested in each case. 

Use the probe to contact at least the following test points:

 

à

Transformer metal bracket

 

à

PE connection on the secondary side of the transformer (luster terminal) 

 

à

Track (blank, non-anodised area) 

 

à

Device flat plug for transformer ground connection 

 

à

Cover (blank, non-anodised area)

All protective earth connections must have a resistance of less than 0.1 Ω.

 

X

Then start an insulation strength test (high voltage test) on the testing device.

Only drives that have passed the device safety test may be operated. 

The results of the device safety test must be documented in a traceable manner along with the serial number of 

the drive. 

After the device safety test, do not remove the device flat plug of the ground connection from the track.

 

X

Carry out the production test as described in the wiring diagram “Automatic sliding doors DCU1-NT/DCU1-2M-NT”.

6.1  Unplugging the cables

 

X

Unplug the rechargeable battery cable from the control unit and secure it for transport.

 

X

Unplug the ground line on the cover from the ground connector.

Summary of Contents for ECdrive H

Page 1: ...ECdrive H EN Pre installation instructions 190486 01...

Page 2: ...Diagrams 6 4 2 Tools and aids 6 4 3 Torques 6 4 4 Components and assembly groups 7 4 5 Bill of material VP Kit ECdrive H 7 5 Pre mounting 8 5 1 Machining the track and cover 8 5 2 Preparing the track...

Page 3: ...age to understand or optimise the operation sequences means additional Information X X Symbol for an action This means you have to do something X X If there are several actions to be taken keep to the...

Page 4: ...pair work must be performed by properly trained personnel authorised by GEZE The country specific laws and regulations are to be observed during safety related tests If unauthorised changes are made t...

Page 5: ...d crushing impact drawing in or shearing spots Risk of injury due to sharp edges on the drive and door leaf Risk of injury during installation through freely moving parts 2 4 Environmentally conscious...

Page 6: ...17 2 0229 Component drawing Leaf spring for cover ECdrive H The diagrams are subject to change without notice Use only the most recent version 4 2 Tools and aids Tool Closer size Tape measure Marking...

Page 7: ...ll of material VP Kit ECdrive H 1 Side plate 2 Transformer ground 3 Transformer 4 Transformer cable 5 Deflection pulley 6 Cable guide 7 Tooth belt 8 Control unit 9 Rechargeable battery 10 Motor gear u...

Page 8: ...over X X Check profiles for damage X X Cut the track and cover to the required length see machining drawings Chapter 4 1 X X Install the line feed 1 and drill holes 2 according to the drawing X X Clea...

Page 9: ...tion of the stop buffers 1 is specified during door leaf installation 5 4 Installing the drive components The exact positioning of the components is given on the drive drawings Illustrated 1 leaf W 70...

Page 10: ...there are no cables near the moving parts Cable guide spacing approx 200 mm X X Fix the cable guide 1 on the track 5 6 Connecting motor gear unit and control unit 3 1 2 X X Route the rotary encoder ca...

Page 11: ...e wire transformer cable 1 to length X X Strip both ends and attach insulated wire end ferrules X X Attach the two plugs 3 to the control unit 2 X X Plug the connector 3 into the control unit 2 3 1 2...

Page 12: ...ing the transformer ground WARNING The track is not earthed if there is a poor connection between earthing jumper 2 and track X X Check whether the setscrews of the earthing jumper 2 penetrate the ano...

Page 13: ...there are no blank points available for the device safety test X X Screw the cable shoe of the cover earthing cable 1 using a countersunk screw 4 serrated washer 3 and hexagon nut 2 X X Connect the e...

Page 14: ...y due to impact and crushing When the rechargeable battery cable 1 is plugged in the pulley on the motor gear unit may move suddenly X X Do not reach into the area of moving parts X X Check whether th...

Page 15: ...s cable and the metal part contacted with the probe is tested in each case Use the probe to contact at least the following test points Transformer metal bracket PE connection on the secondary side of...

Page 16: ...nce fr geze com www geze fr Hungary GEZE Hungary Kft E Mail office hungary geze com www geze hu Iberia GEZE Iberia S R L E Mail info es geze com www geze es India GEZE India Private Ltd E Mail office...

Reviews: