ECdrive H
5
Fundamental safety notes
2.3 Safety-conscious working
à
Secure workplace against unauthorised entry.
à
Use only the cables specified on the cable plan provided. Cables must be shielded in compliance with the
wiring diagram.
à
Secure loose, internal drive cables with cable ties.
à
Before working on the electrical system:
à
Disconnect the drive from the 230 V mains and secure it against being switched back on again. Check isolation
from power supply.
à
Disconnect the control unit from the 24 V rechargeable battery.
à
Note that if an Uninterruptible Power Supply (UPS) is used, the system will still be supplied with voltage despite
the fact that the power supply is disconnected.
à
Always use insulated wire-end ferrules for wire cores.
à
Make sure of sufficient lighting.
à
Risk of injury with opened drive. Hair, clothing, cables, etc. can be drawn in by rotating parts.
à
Risk of injury caused by unsecured crushing, impact, drawing-in or shearing spots.
à
Risk of injury due to sharp edges on the drive and door leaf.
à
Risk of injury during installation through freely moving parts.
2.4 Environmentally conscious working
à
When disposing of the door system, separate the different materials and have them recycled.
à
Do not dispose of batteries and rechargeable batteries with household waste.
à
Comply with the statutory regulations when disposing of the door system and the batteries/rechargeable
batteries.
2.5 Safety notes related to transportation and storage
X
Do not throw, do not drop.
X
Avoid heavy impacts.
à
Storage temperatures under –30 °C and above +60 °C can result in damage to the device.
à
Protect against humidity.
à
Dry, well ventilated, closed, weather-proof and UV-protected rooms are suitable as storage areas.
2.6 Qualification
Observe country-specific regulations!
Applicable in Germany:
Companies that carry out the pre-assembly of sliding door drives for escape routes must be licensed as an expanded
manufacturing facility by the testing institution that issued the type approval certificate.