IQ lock AUT, EL / EL DL, EM / EM DL, C / C DL, M / M DL
11
Installation
4.3.1 Installation note
Correctly installed strike plate
Incorrectly installed strike plate
1
6
7
2
4
3
1
8
2
4
3
Solution with special strike plate
Position of the cross latches and crossbars in the
strike plate
1
2
4
3
*
5
3–7 mm
9
12
12
11
10
1
Door frame
2
Door
3
IQ lock
4
Strike plate
5
Clearance 3-7 mm
6
Cavities in the profile must be filled
7
Ensure entry areas are level
8
Lock does not enter
process function not guaranteed
9
Strike plate
10
Control latch
11
Cross latches
12
Crossbar (must run freely)
* Lipped strike plate that can be shortened (strike plate that can be shortened in width)
à
The clearance must be 3-7 mm between flat face plate and strike plate when the door is closed
à
Entry edges must be rounded
à
Make sure the cross latches move into place evenly