IQ lock AUT, EL / EL DL, EM / EM DL, C / C DL, M / M DL
12
Electrical connection
5
Electrical connection
X
Use wire-end ferrules for wire cores.
à
Work on the electrical equipment (IQ AUT, IQ lock EL, IQ lock EL DL, IQ lock EM, IQ lock EM DL) may only be
performed by a qualified electrician.
à
The electrical connection work must be carried out in accordance with the relevant regulations of the VDE and
local utility companies.
The electrical connection for the motor locks (IQ AUT, IQ lock EL, IQ lock EL DL) and lever locks (IQ lock EM,
IQ lock EM DL) must be carried out according to the enclosed wiring diagrams.
The technical data listed (see chapter 4) must be taken into account:
à
The nominal voltage of the motor / magnet in the lock with the output voltage of the power supply or device
to be actuated.
à
The power consumption of the motor / magnet with the output power of the power supply or device to be
actuated.
à
The maximum switching power of the switching contacts with the respective power to be switched.
5.1 Motor lock control MST 210 in connection with IQ lock EL / IQ lock EL DL
5.1.1 Connections
X10 Cover monitoring (OUT)
23 NC
22 COM
X8 Cylinder contact /
Sabotage (OUT)
25 NO / NC
24 COM
X5 Door contact (IN)
6 NO / NC
2 24V ext.
X4 Smoke detector (IN)
9 NC
8 COM
X
A jumper must be inserted if
no smoke detector is used.
See the following pages for
further application options
(24V)
X3 Bolt switching contact
(OUT)
21 COM
20 NO
X6 Mode of operation (IN)
4 Day / night
2 24V ext.
5 Release
2 24V ext.
Jumper
JP1
Smoke detector function
JP2 12 V / 24 V
23
2
2
X10
24
25
X8
26
X5
89
X4
20
2
1
X3
5
2
X6
4
2
3
1
X7
121
3
X2
10
11
16
17
14
15
18
19
23
1
X1
27
28
34
35
32
33
38
39
36
37
JP1
JP2
F1
F2
X9
X11
LED1
ON
1 2 3 4
LED6
LED5
LED4
LED3
LED2
LEDs
LED1 Supply voltage
LED4 Fault/alarm
LED2 Day/night (day=on)
LED5 Door handle
LED3 Release
LED6 Door status
X7 Supply
1 GND in
3 12V / 24V DC in
X1 Lock
27 Cable black
28 Cable red
2 Cable blue
31 Cable pink
32 Cable grey
33 Cable yellow
34 Cable green
35 Cable brown
36 Cable white
37 Cable violet
38 Cable red/blue
39 Cable grey/pink
X2 Outputs
10 Relay day/night COM
11 Relay day/night NO
12 Relay release COM
13 Relay release NO
14 Relay fault/alarm COM
15 Relay fault/alarm NC
16 Relay door handle COM
17 Relay door handle NO
18 Relay door status COM
19 Relay door status NO
X9 RS485 interface
X11 Programming interface
Summary of Contents for IQ lock AUT
Page 56: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 56 Wiring diagrams ...
Page 66: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 66 Annex ...
Page 68: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 68 Annex ...
Page 70: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 70 Annex ...
Page 71: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 71 Annex ...