IQ lock AUT, EL / EL DL, EM / EM DL, C / C DL, M / M DL
32
Wiring diagrams
6.7 IQ lock EL with TSA160 NT (-F, -I), TZ 320 SN and activation
X
Follow the installation instructions for IQ lock.
X
Heed the wiring diagram for TSA160 NT, TSA160 NT-F, TSA160 NT Invers.
X
Heed the wiring diagram for GEZE SecuLogic RWS (TZ 320).
X
Disconnect the internal programme switch of the door drive.
X
For 2-leaf door drives connect the control to the active leaf.
X
Set the parameters on the control DCU2, DCU2-F, DCU-I:
à
with DPS: Set parameter
®®
(
21
) (bar message) to
0 2
(electric strike) and
TO
(
2 0
) (electric strike type) to
0 3
(motor lock).
à
with ST220: Set Input signals
Bolt signal to electric strike.
Set Door parameters
Electric strike type to motor lock.
à
Voltage supply of the MST 210 from separate power supply NT 19.2-24 or from the DCU 5 control
à
The GND of the DCU5 (terminal TOE no. 1)
The following settings must be made on the TZ 320:
à
Set Output 1 to “BA drive”
à
Set Output 2 to “Activation drive”
à
Voltage supply of the MST 210 from separate power supply NT 19.2-24 or from the DCU 5 control
à
The GND of DCU5 (terminal TOE no. 1) must be connected with the GND in the MST 210 (terminal X7 no. 1),
even when a separate power supply is used.
à
The day function on the lock cannot be used with analogue programme switches (DPS / TPS / MPS).
Summary of Contents for IQ lock AUT
Page 56: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 56 Wiring diagrams ...
Page 66: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 66 Annex ...
Page 68: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 68 Annex ...
Page 70: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 70 Annex ...
Page 71: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 71 Annex ...