Technical data
4
Technical data
4.1 IQ lock
ID No.
See price list
IQ lock function
à
Panic function
à
Mechanical self-locking
à
Split cross latch
Additional function IQ lock EL
à
Motor-driven unlocking < 1 second
à
Three operating modes (night / secured by day / permanently unlocked)
à
Electrical time-out function
à
Feedback contacts for lock states
à
Optional sabotage monitoring or cylinder contact
Additional function IQ lock EM
à
Outside handle, electronically engageable
à
Feedback contacts for lock states
à
Optional sabotage monitoring or cylinder contact
Additional function IQ lock C
à
Feedback contacts for lock states
à
Optional sabotage monitoring or cylinder contact
Dimensions (without face plate)
15.2 × 165 × b 15.5 mm (W × H × D)
Operating voltage
IQ lock EL: 12–24 V DC
IQ lock EM: 12 V DC, 24 V DC, 48 V DC
IQ lock C: 24 V DC
Current consumption IQ lock EL
160 mA at 12 V DC
max. 1 A briefly at 12 V DC
80 mA at 24 V DC
max. 500 mA briefly at 24 V DC (incl. MST 210)
Current consumption IQ lock EM
350 mA at 12 V DC
210 mA at 24 V DC
105 mA at 48 V DC
Max. contact rating of the relays
30 V DC / 500 mA
Resistance to forcing
10,000 N
Technical specification
à
Perfectly closing doors with door closer
à
Always use genuine GEZE strike plate
à
Clearance between face plate and strike plate 3–7 mm
à
No door seals which cause pressure
à
Crossbar projection must be horizontal
Climate / surroundings
à
Service temperature: –10 … +50 °C, max. 75 % rel. hum., no condensation
à
Storage temperature: –20 … +50 °C, max. 75 % rel. hum., no condensation
à
Sprinkling not permissible
à
Not suitable for use in very dusty atmosphere (e.g. corn mills)
à
Not suitable for use in aggressive or highly corrosive atmosphere
(e.g. chlorinated swimming baths)
à
Not suitable for vibration (e.g. vehicles)
à
Cannot be used in potentially explosive atmospheres
Approvals
à
EN 179 Emergency exit devices
à
EN 1125 Panic exit devices
à
EN 14846 Electro-mechanical locks
à
EN 1634 Fire resistance and smoke protection test
à
VdS
à
CE
Summary of Contents for IQ lock AUT
Page 56: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 56 Wiring diagrams ...
Page 66: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 66 Annex ...
Page 68: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 68 Annex ...
Page 70: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 70 Annex ...
Page 71: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 71 Annex ...