Description
3.4.2 Mechanical programme switch MPS (optional)
à
Can be connected in addition to the operating modes push button (21).
At the mechanical programme switch MPS, the mode of operation for
the system is selected and the corresponding programme is displayed.
The mechanical programme switch is accessible for everyone without
a key switch.
Mechanical programme switch MPS
With the mechanical programme switch MPS-ST, selection of the
modes of operation is disabled if the key provided has been removed.
Mechanical programme switch MPS-ST
with integrated key switch
3.4.3 Display program switch (optional)
à
Additionally, it can be connected to the internal operating modes push button.
If a dot appears in the bottom right-hand part of the display,
maintenance is due.
OFF
Display programme switch
If a dot appears in the middle of the display, the door has not
yet been fully initialised after the mains voltage has been
switched on.
Initialisation is carried out automatically when the drive opens
and closes the door.