Powerturn
8
Description
3.3 Overview of the modes of operation
The following modes of operation can be set on the Powerturn:
à
Automatic mode
à
Exit only
à
Hold open
à
Night mode
à
OFF
Mode of operation
MPS/MPS-ST*
DPS**
Explanatory notes
Key
Display
Automatic
aU
Door opens and closes again.
The inside and outside activation devices are active.
Refer also to Chapter 3.5.
à
Opening of 2 leaves
When the keys are pressed simultaneously, the
mode of operation changes between 1-leaf open-
ing and 2-leaf opening.
à
Opening of 1 leaf
On the DPS the LED
is lit in 1-leaf operation.
Exit only
ls
Door only opens and closes if someone exits.
Only the inside activation devices are active.
Hold open
DO
Door remains open.
Night mode
Na
Door opens and closes only when activated using
the key switch The inside and outside activation
devices are inactive.
OFF
OFF
OFF
Of
Door is enabled and can be moved by hand. The
inside and outside activation devices are inactive.
*
mechanical programme switch (MPS)/mechanical program switch with integrated key switch (MPS-ST)
**
display programme switch
3.4 Operating elements
The modes of operation can be set using the following operating elements:
à
Operating modes push button (21) on the door drive (refer to chapter 3.4.1)
à
Mechanical programme switch MPS with/without integrated key switch (optional) (see chapter 3.4.2)
à
Display programme switch (optional) (see chapter 3.4.3)
3.4.1 Operating modes push button with operating modes display
The operating mode on the door drive can be selected using the operating modes push button (21). The operat-
ing modes display (21) lights up in the colour of the current mode of operation:
Operating modes displays
Mode of operation
Colour of the operating modes display
(21)
Off
–
Night mode
red
Exit only
white
Automatic
green
Hold open
blue
Information and fault displays
State
Colour of the
operating modes display (21)
The control has not been taught
yellow (light on permanently)
The control has not been initialised yet
lights up in the colour of the current mode of operation periodically inter-
rupted by two brief flashing impulses (1 Hz)
One or more faults are queued
flashes quickly (10 Hz) in the colour of the current mode of operation
The operating modes push button is deactivated operating modes display is switched off
In the Off mode of operation, there is no fault display on the operating modes display (21).