TSA 160 NT
23
Configurable inputs
11.3 Emergency lock
WARNING
Danger of injury due to crushing and shearing!
The safety sensors and obstruction are not evaluated. The door closes with the set force.
X
If the door closes unexpected, move out of the danger zone.
The emergency lock is not permitted with lipped doors and on emergency exits.
à
The configurable input PE2 can be used to connect an emergency lock switch.
à
When the emergency lock switch is activated, the contact is closed and 17.83 V is applied to the input PE2.
The door closes and locks. The contact sensors KI, KA and KB as well as the safety sensors are blanked.
Mode of operation hold open is aborted.
à
The function requires a 20 kOhm terminating resistor for proper function.
à
The door remains closed as long as the emergency lock signal is applied to the input.
à
Setting the parameters:
à
DPS:
Set
e2
to
07
(“emergency lock 20kOhm normally opened contact”).
à
ST220: Set “PE2 function” to “emergency lock 20kOhm NO”.
à
S1, S2: Set parameter 18 to 07 (“emergency lock 20kOhm NO”).
PE2
24V
PE3
24V
52
2
PE2
PE3
oder
53
2
20 k
Ω
11.4 Additional contact sensors (P-KI, P-KA)
à
The configurable inputs can be used to connect additional closer contacts as contact sensors inside or contact
sensors outside.
à
Setting the parameters:
à
DPS: Set
e1
or
e2
to
0 8
for inside contact sensor or to
0 9
for contact sensor inside.
à
ST220: Set “PE1 function” or “PE2 function” to “P-KI activation NO” or “P-KA activation NO”.
à
S1, S2: Set parameter 17 or 18 to value 08 for contact sensor inside or to the value 09 for contact sensor outside.
à
Information see contact sensor inside (KI) or contact sensor outside (KA)
11.5 Switch functions
General points
à
Upon activation, the output of the push button is closed (24 V applied to the PE1 or PE2 input).
à
In the case of 2-leaf systems the push button can be connected to the active leaf control or to the passive leaf control.
X
Set the hold-open time at the active leaf control.
à
If the push button is connected to the passive leaf control, both door leaves open when the switch function is
activated, even if the “1-leaf” mode of operation is set if the passive leaf drive is switched on (internal pro-
gramme switch in position “I” or “II”).
11.5.1 Switch function
Setting the parameters:
à
DPS: Set
e1
or
e2
to
1 0
for:
1st switch contact = open door / 2nd switch contact = close door
If no second switch contact takes place, the door remains open until the mode of operation is changed.
In the case of a 2-leaf drive, 2-leaf opening takes place if the push button is connected to the passive leaf drive.
à
ST220: Set “PE1”, “PE1 function or PE2 function” to “Push button NO” for:
1st switch contact = open door / 2nd switch contact = close door
à
S1, S2: Set parameter 17 or 18 to value 10 (Push button NO) for:
1st switch contact = open door / 2nd switch contact = close door
If there is no second switch contact, the door remains open until the mode of operation is changed.