Planungsunterlage TSA160 Datei 84338PuTSA160_GB_200999_.p65

1400

1200

1000

100 130 160 190 220 250

Leaf width [mm]

Leaf weight [kg]

Leaf width

Hinge centre [mm]

Leaf width

pushing function

pulling function

minimum spring

pre-tension

maximum spring

pre-tension

minimum spring

pre-tension

maximum spring

pre-tension

Closer size acc. to
EN 1154

moment exerted by the
closing spring when door
is opened automatically

moment exerted by the
closing spring when door
is closed

moment that has to be
exerted manually to open
the door

Size 3 . . . . . . . . Size 6

20 Nm . . . . . . > 60 Nm

8 Nm . . . . . . . 30 Nm

150 Nm . . . . . . . 90 Nm

70 Nm . . . . . . 40 Nm

35 Nm . . . . . . . 110 Nm

13 Nm . . . . . . 45 Nm

Closing moments:

Opening moments:

Hint:

The doors have to be equipped with hinges suitable for automatic function.
A door stopper is recommended in any case.

TSA 160 maximum leaf width as a function of leaf weight

Summary of Contents for TSA 160

Page 1: ...1 GEZE PlanungsunterlageTSA160Datei84338PuTSA160_GB_200999_ p65 TSA 160 GB Swing Door Drive for Automatic Doors Planning document ...

Page 2: ...A part 1 edition 98 2 consecutive number 6 14 of DIN 18 263 4 the manufacturer GEZE GmbH Postfach 1263 D 71229 Leonberg the production plant GEZE GmbH Reinhold Vöster Str 21 29 D 71229 Leonberg in accordance with the results of the product tests carried through by the MPA NRW internal product control carried through by the producer foreign control carried through by the MPA NRW The manufacturer is...

Page 3: ...lements 16 Safety sensors 17 Side view and installation dimensions TSA 160 18 Side view and installation dimensions TSA 160 and TSA 160 F IS 20 Side view and installation dimensions TSA 160 pulling 22 Side view and installation dimensions 1 and 2 leafs TSA 160 Z and TSA 160 Z IS 24 Cable plan single leaf door 26 Cable plan single leaf smoke and fire proof door incl central smoke control unit 27 Ca...

Page 4: ...s kindergardens Where energy has to be saved Exterior doors corridor end doors Draught proofsystems Workshops ateliers studios Where hygiene is required Foodmanufacturingshops pharmaceuticalindustry Hospitals surgeries Social rooms toilets Where safety is the first priority For safety locks and access control For fire prevention purposes fire and smoke prevention type TSA 160 F on single leaf and ...

Page 5: ...pposite hinge side For single leaf doors TSA 160 only one system for door DIN left or DIN right retrofittable and usable for either pullingorpushingversion TSA 160 F for smoke and fire proof doors pushing For double leaf doors Intermediate cover possible TSA 160 IS includinginvisibleclosingsequenzcontrol concealedunderthecover TSA 160 F IS for smoke and fire proof doors TSA 160 IS TS automatic 2nd...

Page 6: ...er control on double leaf doors TSA 160 162 as master slave combinationwithonlyone combined control for both drives of double leafdoors TSA 160 IS TS pushingorpullingincl integratedclosercontrol 2ndclosingleafincl automaticfunction 1st closing leaf incl door closer function and permanently openposition Hinge side pulling incl guide rail Opposite hinge side pushing incl linkage Hinge side pulling i...

Page 7: ...y a mains PC board for power cutoff F accessories and the normal door closing function the drive is maintained Door closers with automatic opening function swing door drive in accordance with DIN 18263 part 4 are therefore an integral part of hold open mechanisms and require approvalbythebuildingsupervisionauthorities TSA 160 F pushing incl DIBt approval for the use on single leaf smoke and fire p...

Page 8: ... proof doors Smoke switch with energy supply e g RSZ 6 probably additional smoke detectors in accordance with the guidelines for hold openmechanisms break key manually operated release button in accordance with the guidelines for hold open electric door opener approved for fire proof doors customer Mounting plate TSA 160 Electric door opener Interrupter button Actuation button Emergency cut out RS...

Page 9: ... time the doors close automatically with all safety elements being active This means that the sensors will stop the movement of the door if a person is within the swing of the door and the door will not close until the obstacle has been removed Smoke heat extracting system fresh air If an alarm has been released by the smoke detector or the fire alarm system the doors are immediately unlocked and ...

Page 10: ...e door opener prevents that the doors can be opened manually To leave the lavatory the user again operates the changeover switch the sign OCCUPIED out side the compartment as well as the control lamp go out By operating the interior pad switch DOOR OPEN the door will immediately open In the case of power failure the user has the possibility to open the door manually by pushing or pulling it open t...

Page 11: ... 160 F IS 1470 mm TSA 160 F IS TS 1260 mm Max weight of leaf 250 kg Max soffitdepth pushingfunction TSA160 350mm pulling function TSA 160 Z 200 mm For dry rooms only ambient temperature 10 to 60 C Adjustablefunctions Opening speed viahydraulicvalve Closing speed within range 75 0 Opening and closing damping viahydraulicvalve Latchingaction viahydraulicvalve Closingforce infinitely EN size 3 6 DIN ...

Page 12: ...n Closer size acc to EN 1154 moment exerted by the closing spring when door is opened automatically moment exerted by the closing spring when door is closed moment that has to be exerted manually to open the door Size 3 Size 6 20 Nm 60 Nm 8 Nm 30 Nm 150 Nm 90 Nm 70 Nm 40 Nm 35 Nm 110 Nm 13 Nm 45 Nm Closing moments Opening moments Hint The doors have to be equipped with hinges suitable for automati...

Page 13: ...ing leaf 1st closing leaf mm mm mm 2 mm 2 mm TSA 160 IS 1470 2800 690 400 1400 pushing TSA160Z IS 1470 2800 690 650 1400 pulling TSA 160 IS TS 1260 2800 690 400 1400 pushing TSA160Z IS TS 1360 2800 690 650 1400 pulling On smoke and fire proof doors Single leaf doors minimum maximum door width door width mm mm TSA 160 F pushing 690 1400 Double leaf doors minimum maximum minimum minimum maximum hing...

Page 14: ...IN 18263 part 4 Intermediate cover and add on cover set All necessary connections and ancilliary parts are aesthetically covered Intermediate cover for optical and functional connection of two drives Add on cover set for single leaf systems to extend to full door width Motor shaft Motor Side elements Hydraulic pump Connecting cable Guide rail for hinge side pulling function Linkage for opposite hi...

Page 15: ...ersupply 230 V AC 10 14 50 60 Hz Powerconsumption 200 VA with 230 V AC The motor is switched off as soon as the preset open position of the door is reached or upon lapse of the preset motor running time Motortemperaturecontrolbyintegratedthermoswitch Powerfailure manualdoorcloserfunction hydraulicallycontrolledclosing Integratedprogramme positionII automaticfunction position I permanently open pos...

Page 16: ... operation Permanentlyopen Explanation Open circuit principle Typicalapplication entrancedoor compulsoryforfire proofdoors The locking process is made by the open circuit principle i e the door remains closed as long as the lock is not live or actuated The door is unlocked either by short term actuation or permanent contact permanently open In the case of power failure the door remains locked and ...

Page 17: ...or If the safety sensor OPEN SA is used the door movement stops as soon as the sensor detects an obstable Wall recognition possible The safety sensor CLOSE SZ actuates the drive of the closing door and opens them again Incl radar on both sides and SA Safetysensor OPEN SZ Safetysensor CLOSE Incl radar on both sides Radar Sensor SA Sensor SZ Radar safety sensors AIR16 Radar Radar FB Width of the lea...

Page 18: ... 9920 Swing door drive TSA 160 size 2 5 incl safety and actuation sensor Side view and installation dimensions TSA 160 Opposite hinge side pushing incl Mounting plate For door widths 690 1400 mm To be used vor TSA160Z Invers as well A Spindleextension optional 24 30 45 mm not illustrated above Linkage pushing Actuation sensor AIR 16 Mounting plate L 690 mm Safety sensor AIR 16 without scales ...

Page 19: ...ounting dimensions for direct mounting Mounting dimensions when mounting plate is used Blind rivet nut If cable entry is from the rear make boring Ø 20 Mounting dimensions safety sensor DIN right door For door widths 900 mm make further tappered boreholes at intervals of 200 mm Dimensions of drive and sensors door DIN right pushing Hinge centre Drive and actuation sensor opposite hinge side Actuat...

Page 20: ...0 F Side view and installation dimensions TSA 160 and TSA 160 F IS For double leaf doors with integrated closing sequence control Opposite hinge side pushing incl mounting plate and steel frame Door widths 690 1400 mm Mounting plate L 690 mm min 5 fixing points dowelS10 Spindle extension A Reset button Linkagepushing for soffit depth A X 0 100 100 200 200 350 without scale Dimensions for direct mo...

Page 21: ...ntegrated closing sequence control TSA 160 F incl external closing sequence control hinge centre hinge centre 1 If cable entry is from the rear make boring Ø 20 Mounting dimensions DIN right pushing Dimensions for direct fixing Mounting dimensions DIN left pushing Dimensions incl mounting plate Drive opposite hinge side Drive opposite hinge side Mounting dimensions when mounting plate is used 690 ...

Page 22: ...00 mm Dimensions for direct mounting of drive Dimensions for mounting of drive with mounting plate mounting plate not illustrated dimensions for safety sensor dimensions for actuation sensor Further details see installation drawing No 70423 9 9921 Swing door drive TSA 160 incl safety and actuation sensor Actuation sensor AIR16 Safety sensor AIR 16 Lever and guide rail incl roller guide Automatic O...

Page 23: ...ulling function Mounting dimensions safety sensor in brackets Safety sensor dimensions in brackets Actuation sensor dimensions in brackets Door hinge axis Mounting of basic drive TSA 160 pulling incl AV 60 mm AV 0 mm Min leaf width 890 mm 950 mm Leaf width FB 890 900 910 920 930 940 950 Door opening angle 110 105 103 97 93 89 85 Drive unit position AV 60 50 40 30 20 10 0 Distance x 29 19 9 1 11 21...

Page 24: ...incl satefy and actuation sensor For door widths 690 1400 mm 2nd closing leaf drive TSA 160Z IS 1st closing leaf drive TSA 160 Z Actuation sensor AIR16 Safety sensor AIR16 Lever and guide rail pulling function with guide rollers Dimensions for direct mounting of drive Further details see installation drawing No 70477 9 9804 Swing door drive TSA 160 Z IS incl safety and actuation sensor without sca...

Page 25: ...m 690 690 690 690 690 703 721 739 Openinganglein degrees 109 113 113 115 115 110 110 105 105 100 100 97 97 95 95 90 Mounting plate TSA 160 Z IS incl integrated closing sequence control 2nd closing leaf drive TSA 160 Z IS hinge side 1st closing leaf drive TSA 160 Z hinge side Mounting dimensions DIN left or right pulling mountingplate directmounting Mounting dimensions safety sensor in brackets hin...

Page 26: ...ting box provided by GEZE Door opener Lock switch contact Sketch A For the installation and operation of the entire system the guidelines ZH1 494 for power operated windows doors and gates issued by the Association for Accident Prevention and Industrial Medicine 53757 Sankt Augustin have to be observed In addition to this the mounting and operating instructions as well as all other documents refer...

Page 27: ...0 6 mm Main switch Emergeny cut off switch Power supply line 230V 50Hz Connected load 200 W Key operated switch inside Contactor inside Programme switch Movement detector inside seesketch A Cable outlet for door drive acc to sketch A Door drive TSA 160F Movement detector outside seesketchA Contactor outside Key operated switch outside Sensor strips and or and or 8 poledoor transitioncable incl con...

Page 28: ...6 mm 3 J Y ST Y 2x2x0 6 mm 4 Cable conduit with Ø16 mm Key operated switch inside Contactor inside Programme switch Movement detector inside seesketch A Cable outlet for door drive Movement detector outside seesketchA Contactor outside Key operated switch outside Sensor strips and or and or Door opener Lock switch contact In addition Wiringdiagram70423 9 9750 Sketch A For the installation and oper...

Page 29: ...ST Y 2x4x0 6 mm 3 J Y ST Y 2x2x0 6 mm 4 Cable conduit with Ø16 mm 5 J Y ST Y 2x0 6 mm Key operated switch inside Contactor inside Programme switch Movement detector inside seesketch A Cable outlet for door drive acc to drawing Movement detector outside seesketchA Contactor outside Key operated switch outside Sensor strips and or and or 1 8 poledoortransitioncableincl connectingbox providedbyGEZE 2...

Page 30: ...actor inside Movement detector inside Sensor strips and or 1 8 poledoortransitioncableincl connectingbox provided by GEZE 2 Doortransitioncable providedbycustomer Sensor strips 2nd closing leaf 1st closing leaf Power supply line 230V 50Hz Fuse 16 A Connected load 2 x 200 W Dooropenerwith latchcontact Rotaryswitchcontact Main switch Contactor inside Contactor outside Contactor outside Movement dete...

Page 31: ...nterior Lamp OCCUPIED 24V 80mA exterior In addition Wiringdiagram70423 9 9750 AuxiliarywiringdiagramWC control70712 9 961 Allow cable to protrude at least 1 m out of the wall IMPORTANT The breaker contact must be installed in close proximity to the door and must not be concealed by the open door Note Any warranty and service agreements will be rejected if GEZE products are combined with third part...

Page 32: ...21 9 Fax 39 0 80 31 64 56 1 E Mail gezebari libero it Benelux GEZE Benelux B V Industrieterrein Kapelbeemd Leemkuil 1 5626 EA Eindhoven Tel 31 40 26 29 08 0 Fax 31 40 26 29 08 5 E Mail benelux nl geze com Austria GEZE Austria GmbH Mayrwiesstraße 12 5300 Hallwang b Salzburg Tel 43 0 662 66 31 42 Fax 43 0 662 66 31 42 15 E Mail austria at geze com Asia GEZE Asia Pacific Ltd Unit 630 Level 6 Tower 2 ...