23
GEZE
Planungsunterlage TSA160 Datei 84338PuTSA160_GB_200999_.p65
14
14
720
260
690
AV
100
[M5]
[ø11]
[200]
[260]
[125]
(50)
(200)
(400)
(600)
(800)
(114)
(Ø10)
Door hinge
axis
For widths of door >900 mm
drill additional tapped holes
at an interval of 200 mm
-
+
M5
M6
-
+
M5
M6
*1)
*1)
708
y
420
625
x
x
625
420
KD
KD
+
-
+ -
708
y
Drive DIN left pulling incl. guide rail and safety sensor
DIN right mirror image
Mounting dimensions for direct mounting,
Rebate DIN left pulling function
Mounting dimensions safety sensor in (brackets)
Safety sensor, dimensions in [brackets]
Actuation sensor, dimensions in [brackets]
Door hinge axis
Mounting of basic drive TSA 160 pulling
incl.:
AV 60 mm... AV 0 mm
Min. leaf width:
890 mm ...
950 mm
Leaf width: FB
890 900 910 920 930 940 950
Door opening angle
110° 105° 103° 97°
93°
89° 85°
Drive unit position AV
60
50
40
30
20
10
0
Distance ± x
29
19
9
-1
-11
-21
-31
Distance y
176 186 196 206 216 226 236
Cable lead-through KD
580 590 600 610 620 630 640
Door hinge axis
Guide rail
Rebate DIN right pulling function
*1) If cable supply is made from the rear, drill hole Ø 20
Door hinge
axis