UFO-NT
13
"Open" and "close" safety sensor
5.2.1 Monitoring closing and opening
1
-UB
+UB
COM
+
SIO
60 mA
Test
SIS
GC 342
BGS
BN
GN
YE
WH
PK
GY
BU
RD
SIO
13
1
GND
4
24VSENS
10 TST
SIO
SIS
11
1
GND
4
24VSENS
10 TST
SIS
GC 342
BS
1
Door transmission cable
GC 342 settings
à
See installation instructions GC 342.
à
GEZE recommends using the optional remote control to change the sensor parameters.
DCU8 settings
X
Setting the "Contact type" parameter:
à
DPS:
Set
s1
and
s3
to
0 2
("NC") (default setting).
à
ST220: Set the "Input signals", "SI1 – terminal SIS", "SI1 contact type" to "NC" and
"SI3 – terminal SIO", "SI3 contact type" to "NC" (default setting).
X
Setting the Function parameter:
à
DPS: Set
f1
to the desired function and
f3
to
0 5
(SIO stop) or
0 6
(SIO stop SF-GF).
à
ST220: Set the "Input signals", "SI1 – terminal SIS", "SI1 function" to the desired function and "SI3 – terminal
SIO", "SI3 function" to "SIO stop" or "SIO stop SF GF".
5.2.2 Monitoring opening
1
SIO
13
1
GND
4
24VSENS
10 TST
SIO
-UB
+UB
COM
+
SIO
60 mA
Test
SIS
GC 342
BS
BN
GN
YE
WH
PK
GY
BU
RD
1
Door transmission cable
DCU8 settings
X
Setting the "Contact type" parameter:
à
DPS:
Set
s3
to
0 2
(NC) (default setting).
à
ST220: Set the "Input signals", "SI3 – terminal SIO", "SI3 contact type" to "NC” (default setting).
X
Setting the Function parameter:
à
DPS: Set
f3
to
0 5
(SIO stop) or
0 6
(SIO stop SF-GF).
à
ST220: Set the "Input signals", "SI3 – terminal SIO", "SI3 function" to "SIO stop" or "SIO stop SF GF".