Configurable inputs
11.2 2-leaf opening and 1-leaf opening
à
The configurable inputs of the active leaf control can be used to change between 2-leaf opening or 1-leaf
opening as required (depending on the parameter setting). For example, this may be advisable if the opening
type is switched by a timer via the available programme switching inputs (NA, LS, AU, DO).
à
A change in the mode of operation is not possible if the analogue programme switch MPS is connected, since
this specifies the "2-leaf opening" or "1-leaf opening".
à
Set the parameters with:
à
DPS: Set
e1
,
e2
or
e3
to
0 3
(switch over summer) or to
0 4
(switch over winter).
à
ST220: Set “PE1 function”, “PE2 function” or "PE3 function" to "2-leaf opening" (switch over summer) or
"1-leaf opening” (switch over winter).
51 PE1
2 24V
PE1 GF
52 PE2
PE2 GF
oder
53 PE3
PE3 GF
oder
11.3 Sabotage
à
The configurable input PE1, PE2 or PE3 can be used to connect an alarm contact which can be used to monitor
a closed (key switch) housing. In the case of a closed housing, the contact is closed and 24 V is applied to input
PE1, PE2 or PE3. When the alarm contact opens, 0 V is applied to input PE1, PE2 or PE3. In this case, the door
remains closed and locked.
If the contact is interrupted, KB is not evaluated in the NA, LS, AU mode of operation. All other functions re-
main the same. Acknowledgement must then take place (delete error).
à
Set the parameters with:
à
DPS:
Set
e1
,
e2
or
e3
to
0 5
(sabotage).
à
ST220: Set "PE1 function", "PE2 function" or "PE3 function" to "Sabotage NC".
51 PE1
2 24V
PE1 GF
52 PE2
PE2 GF
oder
53 PE3
PE3 GF
oder
11.4 Active leaf closed position
Feedback from a door contact attached in the closed position, connected to PE1, PE2, or PE3.
The door contact closes once the door leaf has reached the closed position(active leaf).
à
Set the parameters with:
à
DPS:
Set
e1
,
e2
or
e3
to
0 6
(closed position door closer GF).
à
ST220: Set "PE1 function", "PE2 function" or "PE3 function" to "closed position GF".