UFO-NT
33
Electric strike
12.2.8 Maintenance due
à
The function is used to signal that maintenance is due for the door drive at a customer building control centre.
à
Set the parameters with:
à
DPS: Set
a1
to
2 0
("Maintenance due" message).
à
ST220: Set "PA1 function" to "Maintenance due".
à
Connecting a building control centre, see chapter 12.2.2, "Fault".
1
Building control centre (provided by customer)
2
Signal input
3
24 V relay, mat. no. 103352
4
Free-wheeling diode
GND
1
2
24V
55
PA1A
56
PA1B
PA
57
PA2
2
1
3
4
12.2.9 Holding magnet GF / SF
For using a holding magnet on the active leaf or passive leaf.
12.2.10 WC timeout
To connect a lamp or a signal to signal when the 30-min. timer has expired for the WC function.
13 Electric strike
X
Connect the electric strike of the active leaf to the active leaf control and the electric strike of the passive leaf
to the passive leaf control.
à
Floating relay contact, switching voltage/current max. 24 V AC/DC, 1 A.
à
Use electric strikes with a duty rating of ED 100.
à
To operate the DPS DPS see chapter 27.4 "DPS (DPS)".
à
To operate the service terminal ST220 see chapter 27.1 "Service terminal ST220".
The state of the drive to which the ST220 is connected is displayed.
X
Press the
button.
X
Select "Active leaf para" or "Passive leaf para" using the
or
key and press the
key.
For further settings, see the descriptions below.
à
Set the parameter Electric strike type with:
à
DPS: Set
TO
to the desired electric strike type, see chapter 27.5 "Service menu DPS".
à
ST220: Set the "Door parameters", "Electric strike type" to the desired type, see chapter 27.3 "Service menu
à
Holding magnet MA 500 with counter plate, mat. no. 024740, for the magnetic locking of emergency exit
doors.
à
Motor lock with panic function GEZE IQ Lock EL for 1-leaf doors.
The GEZE IQ Lock EL is a self-locking anti-panic motor lock with external control.
See wiring diagram for motor lock IQ Lock EL.
IQ Lock SecuLogic set
(Motor lock PZ-bored, complete, incl. flat face and strike plate, motor lock control, power supply cable for control,
reed switch contact as well as open drip loop)
Name
Distance [mm]
Backset [mm]
Mat. no.
IQ Lock EL 9235
92
35
103601
IQ Lock EL 9240
92
40
115013
IQ Lock EL 9245
92
45
103699
IQ Lock EL 7255
72
55
103700
IQ Lock EL 7265
72
65
103701
IQ Lock EL 7280
72
80
106571
IQ Lock EL 7210
72
100
106572
à
When using a motor lock without bolt message, the parameters “Opening delay day” (time in which the motor
lock can unlock before the drive opens the door; only applies in the operating modes automatic and exit only)
or “Opening delay night” (time in which the motor lock can unlock before the drive opens the door; only ap-
plies in night mode) must be set to give the motor lock time to unlock.
à
Set parameter
D l
for opening delay day or
D N
for opening delay night with:
à
DPS: Set
D l
to the required time (0 s … 9 s).