UFO-NT
43
Commissioning and service
20.3 Teaching a 1-leaf system
Step
Actions
ST220 display
DPS display Service LED
display (5
1)
1
X
Select parameter “Start teaching” and press the
ENTER key.
X
Select 1-leaf system.
Start teaching
1
X
Start the respective teaching in DPS (NT)
à
LE for 1-leaf system.
LE
1
X
Exit display.
○ ● ● ● ●
2
A beep sounds (1 x 0.5 s).
3a
The drive is in the condition on delivery or has been set to the default setting. The following system parameters are
displayed in succession:
X
Set system parameter for the present object.
X
When teaching using the service interface,
the parameters must be set before the
teaching begins, see chapter 27.5 “Service
buttons S1 and S2”.
Type of installation
Leaf width
Door weight
Close safety sensor
Open safety sensor
OH
F8
t6
S1
S3
à
Testing:
à
24 V or energy-saving mode for GC 338
à
GND for GC 334, GC 342
Testing
Electric strike type
Bolt message contact type
tE
to
rr
3b
If the teaching is carried out again, the parameter menu 3a is no longer displayed.
4
X
Open door leaf manually up to the desired open
position.
The drive gives out an an acoustic warning signal in
order to display max. drive-related open positions. The
interruption of the warning signals is always shorter,
extending to the max. open position.
à
If the beep continues to sound, the the
door leaf is in the range of the max. open
position (±3°).
à
In this setting, there is a possibility that the
drive does not work properly or is perma-
nently damaged.
X
Carry out the teaching run again to avoid this.
Open manually
L1
● ○ ○ ○ ●
5
X
Move the door leaf by hand to the desired closed
position.
X
Push the input enter key.
The display is acknowledged.
Close manually
L2
● ○ ○ ● ○
6
If GC 338 is installed:
X
Press the "Teach In" key on the sensor and wait for 10
s.
Else (if GC 338 is not installed), proceed with point 7.
Press “Teach in”
L3
● ○ ○ ● ●
7
X
Push the input enter key.
The display is acknowledged.
Press “Teach in”
L3
● ○ ○ ● ●
8
The movement run starts automatically after 2 s.
à
Wall blanking is taught.
In this run, sensors are not switched as “active”.
à
An obstacle is not identified.
à
If a blockage is detected within the movement run,
fault 25 is set.
The teaching run must then be repeated.
Movement run
L4
● ○ ● ○ ○
9
When the door leaf arrives in the closed position at the end of the movement run, a beep (2 × 0.5 s) is sounded.
10
The teaching run is finished and the display depends
upon the peripheral device.
The main menu is displayed The main
menu is
displayed
The mode of
operation is
displayed