UFO-NT
5
Notes
1
Notes
1.1 Important safety instructions
To ensure personal safety, it is important to follow these safety instructions.
X
Keep these instructions.
à
Only specialists authorised by GEZE are permitted to carry out installation, commissioning and maintenance
work.
à
Unauthorised modifications to the system release GEZE from liability for any resulting damages.
à
GEZE makes no guarantee for combinations with third-party products. In addition, only original GEZE parts
may be used for repair and maintenance work.
à
Connection to the mains voltage must be carried out by a qualified electrician. The mains connection and
equipment ground conductor test must be performed in accordance with VDE 0100 Part 610.
X
The customer must install a circuit breaker as a mains separator, whose rated value is aligned to the type, pro-
file, method of installation and the ambient conditions of the local power supply line. The circuit breaker must
have a minimum and maximum rating between 4 A and 16 A.
à
Attach safety stickers to glass leaves (mat. no. 081476).
X
In accordance with Machinery Directive 2006/42/EC, a safety analysis must be performed and the door system
must identified in accordance with CE Identification Directive 93/68/EEC before the door system is commis-
sioned.
à
Observe the latest versions of directives, standards and country-specific regulations, in particular:
à
ASR A1.7 "Directives for doors and gates"
à
EN 16005 "Power operated pedestrian doorsets – Safety in use – Requirements and test methods"
à
"Guidelines for hold-open systems"
à
DIN VDE 100-600 "Installation of low-voltage systems - Part 6 Tests"
à
DIN EN 60335-2-103 "Household and similar electrical appliances; Particular requirements for drives for
gates, doors and windows"
à
Accident Prevention Regulations, in particular BGV A1 (VBG1) "General Regulations"
BGV A3 (VBG4) "Electrical Installations and Resources"
1.2 Installation information
X
Only use the cables prescribed in the cable plan provided. Cables must be shielded in compliance with the
wiring diagram.
X
Always use insulated wire-end ferrules for wire cores.
X
Insulate wires that are not used.
X
Secure loose, internal drive cables with cable ties.
X
Observe the maximum permitted overall current drain required to supply the periphery.
1.3 Safe operation
X
Secure the workplace against unauthorised entry.
X
Pay attention to the swivelling range of long system parts.
X
Secure control box against falling.
X
Before working on the electrical system, disconnect the power supply (mains and battery) and check that no
voltage is present. Note that if an uninterruptible power supply (UPS) is used, the system will still be supplied
with power despite the fact that the power supply is disconnected.
à
Risk of injury by moving parts (drawing in of hair, clothing, ...) when a drive is opened.
à
Risk of injury caused by unsecured crushing, impact, drawing-in or shearing spots.
à
Risk of injury caused by sharp edges in the drive.
à
Risk of injury due to glass breakage.
à
Danger of injury through link arm or lever arm snapping back. Disconnect motor from the control only if
spring is not under tension.
à
Danger of injury when working at heights.
à
Only operate the drive with a connected latching action switch.
1.4 Inspection of installed system
X
Check the measures for securing or preventing crushing, impact, shearing or pull-in spots.
X
Check the function of the presence sensors and movement detectors.
X
Check the protective earth connection to all metal parts that can be touched.