UFO-NT
51
Service menu
Display immediately after connection
G E Z E
Service terminal
2.1
XXXXXYWWJJZZZZZZV
Software version ST220 V2.1
Serial number ST220
27.1.2 Service mode ST220
à
The change to service mode occurs when the service terminal is connected to DCU8.
à
Service is possible in the LS, AU and DO modes of operation.
à
In service mode, the door remains in operation in the current mode of operation (not when teaching is activated).
à
The hardware version is detected above software version 1.8. In case of a disparity after “D1” or “F1”, the drive
switches to safety shutdown and sets the error “Incorrect HW/SW combination”.
Display after connection to the door control
UFO-NT U1.8 F0
DCU800
Automatic
closed
Drive type
Software version V U1.8, Hardware version F0
Basic board DCU200
Mode of operation
Door status
27.2 Connecting service terminal ST220
Service terminal ST220 is connected to connection board DU802 (3) using the bushing for the 3.5 mm TRS con-
nector (1) or alternatively at the connector plug for DPS (2).