UFO-NT
61
Service menu
Name
1 Sub-menu
2 Sub-menu
3 Sub-menu
Explanation
PE2 function
not used
MPS MPS
For connection of an MPS
Switch over summer
NO
For the connection of a push
button for the summer function.
Switch over winter
NO
For the connection of a push
button for the winter function
Sabotage NC
see PE1
Closing position GF
NO
Closed position contact for the
door leaf
à
For 1-leaf door
à
For 1-leaf door drive with
manual passive leaf (door
closer):
Closed position contact for
the active leaf
à
For 2-leaf door:
Active leaf contact to GF
control; passive leaf contact
to SF control
Emergency
lock.20KOhm
NO
The input can be used to con-
nect an emergency lock switch.
When the emergency lock
switch is activated, the contact
is closed and 24 V is applied to
the input.
The door closes and locks.
The contact sensors KI and KA
are hidden. The safety sensors
and the obstacle detection
remain active. The door remains
closed as long as the emer-
gency lock signal is applied to
the input.
P-KI activation NO
Additional contact sensors (P-KI,
P-KA). For connection of addi-
tional normally open contacts
P-KA activation NO
Switch function
NO
see PE1
Switch function OHZ
NO
see PE1
Stop 12 kOhm NO
For the connection of a stop
push button with 12 kOhm
terminating resistor
Reset-switch
NO
For restarting the drive function
as reset.
Double push button
NO
Open 1× press = 1 leaf leaf.
Open 2× press = 2 leaf leaf.
Stop NO NO
For connection of a stop push
button
Stop NC NC
For connection of a stop push
button
Closed position SF
closed position contact for
the passive leaf for 2-leaf door
with manual passive leaf (door
closer):
Stop 20 kOhm
For the connection of a stop
push button with 20 kOhm
terminating resistor
WC control unit
Connection to the internal push
button for the WC function.