UFO-NT
62
Service menu
Name
1 Sub-menu
2 Sub-menu
3 Sub-menu
Explanation
Fire alarm
If active, the door opening
torque function with fire alarm
torque is set for the duration.
1-leaf opening
In 2-leaf systems, when the
signal is active on the active leaf
only 1 leaf is opened.
Display only for 2-leaf drives.
PE3
current state
PE3
Z-> not active
K->not used
F->not used
PE3 function
not used
MPS MPS
For connection of an MPS
Switch over summer
NO
For the connection of a push
button for the summer function.
Switch over winter
NO
For the connection of a push
button for the winter function
Sabotage NC
see PE1
Closed position GF
NO
Closed position contact for the
door leaf
à
For 1-leaf door
à
For 1-leaf door drive with
manual passive leaf (door
closer):
Closed position contact for
the active leaf
à
For 2-leaf door:
Active leaf contact to GF
control; passive leaf contact
to SF control
Emergency
lock.20KOhm
NO
see PE2
P-KI activation NO
Additional contact sensors (P-KI,
P-KA). For connection of addi-
tional normally open contacts
P-KA activation NO
Switch function NO
see PE1
Switch function OHZ NO
see PE1
Stop 12 kOhm NO
For the connection of a stop
push button with 12 kOhm
terminating resistor
Reset-switch NO
For restarting the drive
Function as reset.
Double push button NO
Open 1× press = 1 leaf open
Open 2× press = 2 leaf open
Stop NO NO
For connection of a stop push
button
Stop NC NC
For connection of a stop push
button
Closing position SF NO
Closed position contact for
the passive leaf for 2-leaf door
with manual passive leaf (door
closer):
Stop 20 kOhm NO
For the connection of a stop
push button with 20 kOhm
terminating resistor
WC control NO
Connection to the internal push
button for the WC function.
Fire alarm NO
If active, the door opening
torque function with fire alarm
torque is set for the duration.