UFO-NT
64
Service menu
Name
1 Sub-menu
2 Sub-menu
3 Sub-menu
Explanation
Holding magnet SF
For setting the holding magnet
(passive leaf).
WC timeout
To connect a lamp or a signal to
signal when the 30-min. timer
has expired for the WC function.
PA2
current state
PA2
Z-> not active
F->not used
K-> NO contact
PA2 function
not used
Gong
If KA is triggered
Fault NO contact
see PA1
Fault NC
Fault MPS
see PA1
Warning signal
The function is used to cyclically
switch a signal transmitter on/
off while the door is opening or
closing.
Electric strike
For the connection of an ad-
ditional electric strike
not used
closed lock
The function is used to signal
the door mode, e.g. to a build-
ing control centre
closed
Not closed
Open
Off
Night
Exit only
Automatic
Hold open
Light control
see PA1
Day/Night changeover
see PA1
not used
Maintenance due
see PA1
Holding magnet GF
For setting the holding magnet
(active leaf).
Holding magnet SF
For setting the holding magnet
(passive leaf).
WC timeout
To connect a lamp or a signal
to signal when the 30-minute
timer has expired for the WC
function.
Testing SI
Current state * Testing SI
Z-> not active
K->not used
F->No testing
Testing SI
No testing
Testing with 24 V
Testing with GND
Energy-saving mode
Testing the safety sensor.
Depending on the type used,
the testing must be set to 24V or
GND here.
Operating mode
LED
current state
Operating mode LED
Z-> not active
K->not used
F->Mode of operation
LED function
Mode of operation
inactive
Disables the mode of operation
LED on the drive.