UFO-NT
72
Service menu
DPS Parameter
Setting values
Explanation
s3
SI3 Contact type
00
Not used
02 NC
04 Frequency
Parameter sets the use of the safety sensor "open" contact type.
c6
KB contact type
00
Not used
01 NO contact
02 NC
The input KB is active in the AU, LS and NA modes of operation.
With 2-leaf assemblies the mechanical contact can be connect-
ed to the active leaf control or to the passive leaf control. Upon
activation, the active leaf opens and, if switched on, the passive
leaf. During activation, the output of the mechanical contact is
closed (24 V applied at the KB input). Active in every mode of
operation when the door is not closed.
c1
KI contact type
00
Not used
01 NO contact
02 NC
The input KI is active in AU and LS mode. With 2-leaf assemblies
the contact sensor inside can be connected to the active leaf
control or to the passive leaf control. Upon activation, the active
leaf opens and, if switched on, the passive leaf opens. Active in
every mode of operation when the door is not closed.
1 a
KI delay
00
… 90
in s x 0.1;
only active when the door is in a closed position. Can be ad-
justed in steps of 0.1.
cO
KA contact type
00
Not used
01 NO contact
02 NC
The KA input is only active in the AU mode of operation. With
2-leaf assemblies the contact sensor outside can be connected
to the active leaf control or to the passive leaf control. Upon
activation, the active leaf opens and, if switched on, the passive
leaf opens. Active in every mode of operation when the door is
not closed.
aa
KA delay
00
… 90
in s × 0.1;
only active when the door is in a closed position. Can be ad-
justed in steps of 0.1.
e1
PE1 function
00 Not used
03
Switch over summer
NO
For the connection of a push button for the summer function.
04
Switch over winter
NO
For the connection of a push button for the winter function
Only for switching over from open 1-leaf to 2, not for actually
opening the door.
05 Sabotage
NC Permanently switched. If the contact is interrupted KB is not
evaluated in the mode of operation "night-time". All other func-
tions remain the same.
06
Closed position GF
NO Closed position contact for the door leaf
à
For 1-leaf Door
à
For 1-leaf Door drive with manual passive leaf (door closer):
Closed position contact for the active leaf
à
For 2-leaf door:
Active leaf contact to GF control; passive leaf contact to SF
control
08
P-KI activation
NO Additional contact sensors (P-KI, P-KA).
For connection of additional normally open contacts
09
P-KA activation
NO
10
Switch function
NO On activation, the output of the push button is closed. With
2-leaf assemblies the push button can be connected to the ac-
tive leaf control or to the passive leaf control. If the push button
is connected to the passive leaf control, both door leaves open
and close on activation of the switch function, even if the pas-
sive leaf control is switched off (bed opening). When the push
button is pressed once, the drive opens the door. When the
push button is pressed again, the drive closes the door.