UFO-NT
75
Service menu
DPS Parameter
Setting values
Explanation
fc
Closing force
01 …
15
… 25
×10 N;
Close static force at the main closing edge.
B
h
Obstacle
01 …
03
… 20
×0.1 s;
Time for which the drive pushes against an obstacle with the set
static force.
of
Opening retention
force
00
… 01 … 07
x10 N;
Constant force on the main closing edge in open position.
cf
Close retention force
00
… 01 … 07
x10 N;
Constant force on the main closing edge in closed position.
fs
Closed position force
00
… 01 … 15
x10 N, force activates in the closed position after the end of the
latching action. Manual passing is more difficult during the set
time. The higher the set force, the longer the duration.
Examples: at 10 N = 0.5 s,
at 150 N = 2 s
6a
Basic function
01
Yes
The drive is in automatic mode.
®®
Lock contact type
01
NO contact
02
NC
Feedback e.g. of a motor lock
sh
SIO manual
00
not active
SIO not active during manual opening
01
active
SIO active during manual opening
ss
SIS manual
00
not active
SIS not active during closing after manual opening
01 active
SIS active during closing after manual opening
ph
Manual rev. closing
00
not active
Reversing in the event of an obstacle within closing following
manual opening: not active.
01
active
Reversing in the event of an obstacle within closing following
manual opening: active.
pa
Auto rev. closing
00 not active
Reversing in the event of an obstacle within closing following
automatic opening: not active.
01 active
Reversing in the event of an obstacle within closing following
automatic opening: active.
s8
ECO mode
00 not active
ECO mode for the control. The 24 V supply to terminal 4 is
switched off in the DO and NA modes of operation.
Note: Activation via access control of KB in the event of NA, as
well as closing the door when switching from DO to AU, requires
a few seconds, as the system first has to boot up.
01 active
8 2
Braking force
01 …
13
… 14
Braking force in de-energised mode; e.g. to stop the door from
slamming shut. To set it such that the door closes in 5 s, see
chapter 21.
sp
Language
00 German
Language of the drive
01
English
02
French
03
Swedish
cs
Delete maintenance
cS
Reset maintenance counter, switch off service LED.
After acknowledgement the display switches between CS
cS
8 6
Operating duration
Co
Total no. of cycles/100
CH Number of cycles manual/100
Display 6-digits each. Scroll downwards with "downward arrow"
Ho
Operating hours/4
So
Operating hours/4 to
next service
Summary of Contents for UFO-NT F
Page 1: ......
Page 7: ...UFO NT 7 Supply terminals 4 Supply terminals DCU800 1 2 24V GND 6 1 RS485 passive leaf 2 FREE ...
Page 79: ...UFO NT 79 ...