UFO-NT
78
Fault messages ST220 and DPS
Fault no. Message
on the DPS
Message on the ST220
Fault description
EEPROM value
–
EEPROM comparison
–
Current measurement error
Error in motor current measurement.
EEPROM time-out
–
Quartz tolerance
–
RAM test
–
ROM CRC test
–
VCC test
–
Quartz failure
–
Motor resistance
–
Comm. M1-M2
–
Wrong HW/SW combination
–
63
63
SW version
Active leaf and passive leaf have different software versions.
65
6 5
Comm. SF-GF
No communication active leaf/passive leaf control.
66
6 6
Locking SF
Electric strike not blocking (passive leaf).
67
67
Unlocking SF
Electric strike not triggering (passive leaf).
70
7 0
Ctrl. DCU800 SF
Internal control fault, collective fault such as fault 60 For detail, log into SF.
71
71
Motor SF short
Motor current too large.
72
7 2
Motor SF
Motor defective.
73
7 3
Permanent activation
Collective fault permanent activation SF inputs.
74
7 4
Rotary transducer SF
Rotary transducer signals faulty.
75
7 5
DCU800 hot
Passive leaf drive, motor or control temperature higher than 95 °C.
76
7 6
Sensor motor SF
Motor temperature sensor defective.
77
77
Passive leaf T-sensor
Control temperature sensor is defective.
78
7 8
Overtemp SF
Motor or control temperature higher than 105 °C.
79
7 9
Passive leaf relay
Motor relay defective, passive leaf.
x .x
Position
Leaf position unknown (dot on left display).
x x .
Maintenance
Maintenance requirement (number of cycles, operating hours, dot on
right display).
8 . 8
DPS
No communication with control - DPS
--
DPS
Operation at programme switch.
O O
DPS
Release operation at programme switch.
0 0
DPS
Change in mode of operation: not possible using programme switch
(internal PS not set to 0, or MPS is configured).
®s
Reset
On starting the teaching procedure: Reset switch not pressed or 24 V RSZ
missing.