UFO-NT
50
Service menu
à
The DO mode is disabled in the event of a fire alarm. The door closes upon expiration of the set servo duration
(
aD
).
à
The additional servo torque (
a O
) must be set for the low energy mode.
à
Safety sensor "open" (SIO) is not evaluated in the event of an activated "Fire alarm" function. The drive pushes
against an obstacle in the opening direction with the set additional servo torque.
à
Safety sensor "close" (SIS) is not evaluated in the event of an activated "Fire alarm" function. The drive pushes
against an obstacle in the opening direction with the set closing torque.
To
rq
ue [N
m
]
0-70 Nm
Servo fire alarm
0-50 Nm
Additional servo torque
0-50 Nm
Additional servo torque
Servo duration 0–20 s
Servo duration 0–20 s
Duration [s]
27 Service menu
27.1 Service terminal ST220
à
Service terminal ST220, mat. no. 087261
à
Commissioning of the drive is possible with the service terminal ST220, software version V2.1 or higher.
à
Connection either via 5-pin plug connector RS485 or using a 3.5 mm TRS connector (with adapter cable mat.
no. 157266)
27.1.1 Operation of ST220
Key
Function
à
Cursor upwards
à
Increase number value
à
Scroll upward (if key is pressed longer than 2 s)
à
Cursor downwards
à
Decrease number value
à
Scroll downward (if key is pressed longer than 2 s)
à
Cancel input
Any input can be cancelled by pressing the x key. The input posi-
tion then changes to the first menu position or one menu level
back.
à
Select
à
Update display
à
Accept new value
Entering values in service terminal ST220
X
Change value with
or
.
X
Confirm using
.
X
Abort using
x
if necessary.
Summary of Contents for UFO-NT F
Page 1: ......
Page 7: ...UFO NT 7 Supply terminals 4 Supply terminals DCU800 1 2 24V GND 6 1 RS485 passive leaf 2 FREE ...
Page 79: ...UFO NT 79 ...