Instruction manual
41
MAPAX2LJRG Battery tool
English
Table 10
When
Why
20 sec
after working cycle
Battery low
2 x
after inserting the battery
Self check
20 sec/2Hz
after working cycle
20 sec/5Hz
while exceeding the temp. limit
Unit too hot
20 sec
20 sec/2Hz
after working cycle
+
1 x
1 x
1 x
after working cycle
Error: the required pressure has not been reached. The Ope-
rator has interrupted the pressing cycle manually while the
motor was not running.
3 x
3 x
3 x
after working cycle
Serious error: the pressure has not been reached while the
motor was running.