background image

 

16 

 

9

 

Declaration of incorporation / Declaration of conformity 

Declaration of incorporation  

within the meaning of Machinery Directive 2006/42/EC 
for partly completed machinery, Appendix II Part B 
 

Declaration of conformity 

within the meaning of EMC Directive 2014/30/EU 
within the meaning of RoHS Directive 2011/65/EU 

We,  
GfA ELEKTROMATEN GmbH & Co. KG 
declare under our sole responsibility that the 
following product complies with the above 
directives and is only intended for installation in a 
door system. 
 
Drive unit 

ST 9.24-25,00 

Part no.: 10002917 00002 
 
 
We undertake to transmit in response to a 
reasoned request by the appropriate regulatory 
authorities the special documents on the partly 
completed machinery. 
 
This product must only be put into operation 
when it has been determined that the complete 
machine/system in which it has been installed 
complies with the provisions of the above-
mentioned directives. 
 
Authorised representative to compile the 
technical documents is the undersigned. 
 
Düsseldorf, 10.08.2018 
 
Stephan Kleine 
CEO 
 

 

Signature 
 
 

  The following requirements from Appendix I of 

the Machinery Directive 2006/42/EC are met: 
1.1.2, 1.1.3, 1.1.5, 1.2.2, 1.2.3, 1.2.6, 1.3.2, 
1.3.3, 1.3.9, 1.5.1, 1.5.2, 1.5.4, 1.5.6, 1.5.7, 
1.5.8, 1.5.9, 1.5.10, 1.5.11, 1.5.13, 1.6.1, 1.6.2, 
1.6.4, 1.7.2, 1.7.3, 1.7.4.3. 
 
Standards applied: 
EN 12453:2001 
Industrial, commercial and garage doors and 
gates - Safety in use of power operated doors - 
Requirements 
 
EN 12604:2017 
Industrial, commercial and garage doors and 
gates - Mechanical aspects - Requirements 
 
EN 60335-1:2012 
Household and similar electrical appliances - 
Safety - Part 1: General requirements 
 
EN 61000-6-2:2005 
Electromagnetic compatibility (EMC) Part 6-2 
Generic standards – Immunity standard for 
industrial environments 
 
EN 61000-6-3:2007 
Electromagnetic compatibility (EMC) Part 6-3 
Generic standards – Emission standard for 
residential, commercial and light-industrial 
environments 

 

 

 

  
 

Summary of Contents for 10002917 00002

Page 1: ...f Installation Instructions ELEKTROMAT ST 9 24 25 00 Model 10002917 00002 en Status 14 02 2022...

Page 2: ...2 GfA ELEKTROMATEN GmbH Co KG Wiesenstra e 81 D 40549 D sseldorf www gfa elektromaten de info gfa elektromaten de...

Page 3: ...12 7 Completing commissioning inspection 13 8 Disposal 15 9 Declaration of incorporation Declaration of conformity 16 Symbols Warning Potential injury or danger to life Warning Danger to life from el...

Page 4: ...experience are what set apart qualified persons They are capable of safely carrying out the tasks involving installation maintenance and modernisation according to the instructions Safe operation The...

Page 5: ...Allow only competent people to carry out the work Disconnect all cables from the power supply Observe valid regulations and standards Use suitable tools Warning Danger to life from falling objects if...

Page 6: ...Temperature range 20 40 60 2 C Operating sound pressure level 70 dB A Maximum output speed OPEN CLOSE for frequency inverter operation 42 42 min 1 Cycles per hour 12 10 4 1 h 1 Max load 9000 N Brakin...

Page 7: ...ven for maximum holding torques or locking torques refer to technical data Connection elements Self locking connection elements with a minimum strength of 800 N mm2 8 8 must be used Utilize the hole d...

Page 8: ...8 Mounting Four holes are provided for mounting...

Page 9: ...sure to use a lifting device that has a sufficient load carrying capacity Ensure that there is sufficient space around the handwheel for safe operation of the friction clutch Notice Gearbox damage fr...

Page 10: ...ing Potential injury or danger to life Disconnect the electric supply to set the friction clutch The friction clutch provides overload protection It is tightened finger tight at the factory Turning to...

Page 11: ...re de energised Observe the applicable regulations and standards Make a proper electrical connection Use suitable tools Performing electrical installation Remove the cover Connect the motor cables and...

Page 12: ...12 5 Motor connection G1 Half wave rectifier M1 Motor Y1 Magnetic brake 6 Limit switch connection F10 Thermal contact...

Page 13: ...ted Protect the output shaft permanently against corrosion Mounting Check that all connection elements consoles torque mounts screws locking rings etc are secure and in proper condition Electrical wir...

Page 14: ...t be observed In an environment that can affect the coefficient of friction of the brake pad atmosphere with oil solvents detergents etc class of protection IP65i must be adopted Note Engage a qualifi...

Page 15: ...se of old devices properly according to local legal regulations Return old devices to the return and collection systems available You can also return GfA products free of charge Please apply enough po...

Page 16: ...omplies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned D sseldorf 10 08 2018 Stephan Kleine CEO Signature The fol...

Page 17: ...17...

Reviews: