2
Technical Data
Type
FT SG50/SG85
Output torque
800
Nm
Output speed
2
rpm
Output shaft / hollow shaft
45,00
mm
Maximum output speed open / close
for frequency inverter operation
3,5 / 3,5
rpm
Maximum holding torque
2900
Nm
Supply voltage
3N~ 400
V
Operating current
1,20
A
Operating frequency
50
Hz
Power factor cos
φ
0,87
Maximum movement per hour
20
h
-1
Class of protection
IP 65
Limit switch range
(maximum revolutions of output shaft / hollow shaft)
1
Temperature range
-10 / +40 (+60)
°C
Pos: null /BA_Module/BA_FC Temperaturbereich/BAFC000001_M002 @ 23\mod_1508937126225_28.docx @ 1055098 @ @ 1
1) When using a temperature range of +40°...+60°C use half of maximum movements per hour.
Pos: null /BA_Module/BA_FD Daten Endschalter/BAFD000002_M001 @ 11\mod_1372072121894_28.docx @ 804291 @ @ 1
Caution - Component damage can result!
The maximum current that can be switched over the limit switch is
1A for 230 V AC and 0.4 A for 24V DC