background image

Transmitter

Master Nº 1 

Master Nº 1 

Master Nº 1 

 

Nº 2 

 

Nº 3 

 

Nº 3 

TRANSMITTER N° 2 MEMORIZATION 

 

 

MENU 

STORE  USER ?  

STORE  USER

 

USER  Nº 001

 

USER Nº 001

 

RELAY: ½  KEY: A  

USER Nº 001

 

START PROG ...

 

See  

“ENTRY INTO THE MAIN MENU”

 

US: 002 RL: ½ KY: A 

STORE USER ?

 

EXECUTED OK  

MORE ....

 

UT: 003 RL: ½ TA : A 

STORE USER ? 

 

EXECUTED  OK  

MORE...

 

TRANSMITTER N° 2 MEMORIZATION

 

Pag. 8

Memorization of the User transmitters

The receiver will memorize the first transmitter in the 
following way:

- USER n. 001: the transmitter will be memorized in 
position 001;

- RELAY 1/2: the transmitter will control relays 1 and 2 
of the receiver;

- KEY A: button A of the transmitter will control relay 1 
of the receiver and button B relay 2.

Each of these parameters can be modified. See "Change 
a number or a letter" (p. 5) and "Modify relay or key 
parameters" (p. 8).

GfA ELEKTROMATEN UK Ltd

Before memorizing the transmitters, we advise you to number 
them, marking each one with an indelible pen. For 
example:transmitter to memorize on Position n. 348. 

 Advice

Choice of “RELAY” or “CHANNEL” parameters

For every transmitter the receiver offers:

- a position to memorize;

- the relay or relays which will be activated by the 

transmitter; 

- the channel or channels used by the transmitter.

The table below show the correspondences between 
what appears on the display and the setting of the 
transmitter buttons on the receiver relays. 

Relay 1/2

Relay  1

Relay  2

Channel A

Channel B

Channel C

Channel D

A on relay 1
B on relay 2

 1

B on relay 2

on relay

 1

C on relay 2

on relay

 1

D on relay 2

on relay

 1

A on relay 2

on relay

 1

on relay

 1

on relay

 2

on relay

 2

on relay

TX 2 keys

TX 4 keys

TX 2 keys

TX 4 keys

 1

on relay

 1

on relay

 1

on relay

 2

on relay

 2

on relay

TX 4 keys

TX 4 keys

 1

on relay

 1

on relay

 2

on relay

 2

on relay

Transmitter

Transmitter

Transmitter

Transmitter

Transmitter

YES

YES

YES

YES

NO+

YES

NO+

YES

Summary of Contents for Multiuser receiver 433/500

Page 1: ...Ltd This product is addressed to manage the access in automatic door control systems This appliance GfA ELEKTROMATEN UK Ltd has been carefully manufactured and checked GfA ELEKTROMATEN UK Ltd has desi...

Page 2: ...Receiver 1 2 Antenna wire 1 3 Assembly screws 4 4 Plugs 4 Characteristics Receiver Local oscillator freq 6 6128 MHz Power supply 12 24 Vac dc Modulation AM ASK FM FSK Number of memorizable users 507 N...

Page 3: ...uiding slits only in those used Proceed to the electric connection fig 10 and thread the wires through the guiding slits fig 9 advice When assembling the equipment outdoors we advise you to protect th...

Page 4: ...nsmitters on the same receiver advice Memorize at least 2 master transmitters If the first transmitter is lost the second will allow access to the parameters GfA ELEKTROMATEN UK Ltd Function and use o...

Page 5: ...mbers from 0 to 9 and the right hand button is used to confirm the choice of numbers See the following example positioning to User zone N 412 1 pulse on YES STORE USER USER N 0 1 2 The receiver indica...

Page 6: ...rsonal key using the Master transmitter Activate the key YES of the Master transmitter The default or personal key has been set MEN 1 1 1 1 1 Transmitter Master N 1 ACCESS CODE SETTING Pag 6 YES NO YE...

Page 7: ...SER Next menu MODIFY USER pag 12 Transmitter Master N 1 Transmitter Master N 1 MENU DELETE Next menu DELETE pag 14 Transmitter Master N 1 Transmitter Master N 1 MENU COPY Next menu COPY pag 16 Transmi...

Page 8: ...ransmitters we advise you to number them marking each one with an indelible pen For example transmitter to memorize on Position n 348 Advice Choice of RELAY or CHANNEL parameters For every transmitter...

Page 9: ...ANSMITTER N 1 MEMORIZATION N 50 US 001 RL KY A STORE USER EXECUTED OK MORE Back to the welcome Message US 050 RL KY A STORE USER TRANSMITTER N 50 MEMORIZATION EXECUTED OK USER N 001 Exit USER N 001 RE...

Page 10: ...pulsive pressing a button on the transmitter activates the relay impulsively Bistable Pressing the button on the transmitter for the first time closes the relay contact pressing it again the contact i...

Page 11: ...smitter NO YES YES Transmitter Master N 1 Master N 1 Master N 1 Master N 1 Master N 1 Master N 1 Master N 1 Master N 1 RELAY 1 EXECUTED OK RELAY 1 PULSE RELAY 1 STEP Back to welcome Message RELAY 1 TI...

Page 12: ...hange a number or a letter p 5 Modify the memory position of a transmitter A transmitter can be moved to a free position It is also possible to exchange the position of 2 transmitters Determine the me...

Page 13: ...nsmitter Master N 1 Transmitter Master N 1 Exit Transmitter Master N 1 Transmitter Master N 1 Transmitter Master N 1 Transmitter Master N 1 USER N 052 RELAY KEY A USER N 052 EXECUTED OK USER N 052 REL...

Page 14: ...nu delete MENU DELETE DELETE USER DELETE FROM 1 TO 500 DEL FROM 1 to 500 ARE YOU SURE Transmitter Transmitter Transmitter Transmitter Transmitter Transmitter CANCELLATION Master N 1 Transmitter Transm...

Page 15: ...Master N 1 DEL USER 001 ARE YOU SURE DEL USER 001 EXECUTED OK DEL FROM 1 TO 500 EXECUTED OK Transmitter DEL MEMORY EXECUTED OK Back to the welcome Message Pag 15 YES NO Back to the welcome Message Bac...

Page 16: ...e appropriate cable supplied in the operating kit using the serial port of the printer see fig 11 Printer setting It is only possible to print from a printer with a serial port Baud rate 2400 Baud Num...

Page 17: ...the previous screen Back to menu COPY US 002 RL 1 KY B US 003 RL 2 KY B Pag 17 GfA 433 500 PASSWORD 54321 INSTALLATION ADDRESS To be completed by hand USER N RELAY KEYS USER NAME Example of print out...

Page 18: ...receiver or into a backup memory Restore the data from another receiver or a backup memory Transfer from another receiver Connect the 2 receivers with the appropriate cable supplied with the operatin...

Page 19: ...ster N 1 Transmitter Master N 1 Automatic Automatic TRANSFER Transmitter Any data contained on the receiver or the backup memory will be totally erased after transfer YES YES YES YES Back to the welco...

Page 20: ...eceiver installed on site Memorize one or more transmitters without moving on site Insert the memory correct way round see fig 14 Keep enough pressure until the message EXECUTED appears to avoid estab...

Page 21: ...n of the receiver installed on site 2 Memorization of the transmitter on site The transmitter has been configured with the self memorization feature you need just to store it into the site receiver Th...

Page 22: ...of the new transmitters just memorized see Copy the memory of a receiver or a backup file 8 Remove the backup memory WARNING After transfer only the first 16 activations of the transmitter key will al...

Page 23: ...e the transmitter is ready to be memorized on site it is necessary to Transmitter Master Automatic Exit Automatic Automatic PROG TRANSMITTER CONNECTED US 001 RL 2 KY D EXECUTED OK PROG TRANSMITTER VER...

Page 24: ...STORE MASTER US 501 RL 1 2 KY A REPLACE US 502 RL 1 2 KY A STORE MASTER US 502 RL 1 2 KY A REPLACE US 502 RL 1 2 KY A REPLACE Pag 24 Replace one or more master transmitters REPLACEMENT OF A MASTER TRA...

Page 25: ...YES YES YES NO Back to the welcome Message Back to the welcome Message Transmitter N 1 Replace Master Transmitter N 1 Replace Master Transmitter N 1 Replace Master Transmitter N 1 Replace Master Tran...

Page 26: ...e a transmitter which has already been memorized Attempt to memorize a transmitter in a memory position which is already occupied Attempt to move a transmitter which has not been memorized or the canc...

Page 27: ...position or replace a position already used Check the charge on the batteries of the transmitter or bring the transmitter near the receiver Transmit a second time If the message persists eliminate the...

Page 28: ...8 GUARANTEE Warranty period 24 months from the production date placed inside In this period if the appliance has any malfuction due to defective component it will be repaired or replaced by the manufa...

Reviews: