Electrical installation
Warning - Danger to life due to electrical current!
Disconnect the cables (mains OFF) and check that the supply is off
Observe the applicable regulations and standards
Ensure proper electrical connection
Use suitable tools
On-site backup fuse and disconnector unit!
Only use current sensitive earth leakage circuit breakers type B for FI-drive units
Connection to the indoor installation via an all-pole disconnector unit, with current
≥ 10 A as per EN 12453 (e.g. CEE plug connector, main switch)
Observe the installation instructions of the drive unit!
Mains supply
3~, N, PE
220 – 400 V
50 - 60 Hz
3~, PE
220 – 400 V
50 - 60 Hz
1~, N, PE, sym.
220 - 230 V
50 - 60 Hz
1~, N, PE, asym.
220 - 230 V
50 - 60 Hz
L1 L2 L3 N PE
L1 L2 L3
PE
N PE
SI 25.15 WS, SI 45.7 WS
N
PE
SI 25.15 WS, SI 45.7 WS