3.1.2 Connecting diagram: mechatronic
GfS e-Bar® 700 73x
Clamp
Signal
Color
Function
1
OV
white
External door reed-contact, recommended otherwise jumper (1-2).
2
GND
black
Mains supply GND
3
OV
yellow
In order to avoid intrusion alarm insert jumper (3-2) - necessary pre-condition door reed-contact (1-2)
4
+ 5 V
green
Release command for FWS 02 (permanent open/single release)
5
+ 5 V
brown
Checkback signal from FWS 02 (FWS 02 circuit is closed, magnet is energized)
6
+ 10 V–30 V
red
Mains supply 10 V–30 V DC
7
OV
violett
Electric pulse for single release or permanent signal for permanent opening (2-7) - not avilable when battery operated
8
NC
grey
Output relay: alarm 30 V/850 mA
9
C
blue
Output relay: alarm 30 V/850 mA
10
NO
pink
Output relay: alarm 30 V/850 mA
11
C
red/blue
Output relay: pre-alarm 30V/850mA. When pre-alarm contact is opened.
12
NO
grey/pink
Output relay: pre-alarm 30V/850mA. When pre-alarm contact is closed.
13
C
Internal emergency exit switch 1 min AWG24
Cable diameter LIVY 4x 0,25
14
C
Internal emergency exit switch 1 min AWG24
15
NO
Internal emergency exit switch 1 min AWG24
16
NO
Internal emergency exit switch 1 min AWG24
17
OV
Key Switch (Reset/ Programming)
18
GND
Key Switch (Reset/ Programming)
19
GND
schwarz
Battery supply GND
20
+ 9 V
rot
Battery supply
}
NC
NO
1
2
4
Incoming
Connection
COMMON
Opener
Shutter
Switching circuit F4
Shiped with 12 wire connector (Jumper PIN 1-2)
1 2 3 4 5 6 7 8 9 10 11 12
13
14
15
16
17
18
19
20